Fig. 32: Lateral alignment of the needle bar
①
②
③
Setting steps
1. Set stitch length to 0.
2. Move the handwheel into the 90° position ( p. 20).
3. Loosen the screw (1).
4. Loosen the screws (2).
5. Loosen the screws (3).
6. Loosen the screw (8).
7. Move the needle bar guide (7) sideways so that the needle bar (4),
8. Tighten screws (1), (2), (3), and (8).
48
(1) - Screw
(2) - Screws
(3) - Screws
(4) - Needle bar
sewing foot bar (5) and presser foot bar (6) are all in a line.
Aligning the needle bar linkage
(5) - Sewing foot bar
(6) - Presser foot bar
(7) - Needle bar guide
(8) - Screw
Service Instructions 969 - 01.0 - 12/2015
⑧
⑦
⑥
⑤
④