Servicing; Troubleshooting; Accessories - Metabo H 16-500 Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

Press the buttons (6) to set the temper-
ature.
Briefly press the "+" /"-" buttons to
increase or lower the set value in 10°
steps. Press the buttons longer to change the
value faster.
Notes:
volume) needs a few seconds to reach the set
value. The triangles flash during this period.
pear when the desired temperature has been
reached.
When the hot air gun is switched off, the last value
set is retained.
Setting air volume:
Press the buttons (7) to set the air
volume or the fan speed.
Program operation:
Four programs for the most frequent types
of work are set in the factory. Press the "P"
button for program operation. A
program 1 appears in the display. Press the
program button again to reach the
programs
,
and
return to normal operation.
Program 1: Forming plastic pipes
Program 2: Welding plastic pipes
Program 3: Removing paint
Program 4: Soft soldering
(For technical data, see chapter 12)
Changing programs and saving:
The values in the four programs can be
changed and saved. To do this, first press
the program button "P" until the program to
be changed is displayed. Set the desired air
volume and temperature. Then push the
save button (10) until the
disappears (approx. 5 seconds). The entered
values are now saved in the program.
Note:
- To return from program operation to the normal
function, press the program button (8) until the
program symbol in the display (9) has disap-
peared.
- The factory settings of the programs are listed in
chapter12.
14
IP3445_H16-500_3Lan_05_110130.indd 14
IP3445_H16-500_3Lan_05_110130.indd 14
Triangles are displayed when
the desired temperature is
being set.
If the desired temperature is
set, the blower (depending
on the selected speed/air
The actual temperature is
measured at the nozzle
outlet. The triangles disap-
for
. Press the button again to
symbol in the display
6.4
Stationary operation
If you wish to use the hot air gun as a
stationary tool, ensure that it is placed on a
safe, anti-slip and clean base.
To use the hot air gun in stationary operation,
place it on the anti-slip bases (5).

7 Servicing

The air inlet (3) with grid must be free of foreign
bodies. Clean the air inlet (3) if necessary.

8 Troubleshooting

Thermal protection
The tools are equipped with 2-stage thermal
protection:
1. * A thermo switch switches off the heater in case
of excessive interference in the air outlet of the
blow-out opening (heat accumulation). However,
the blower continues running. When the blow-out
opening is free again, the heater cuts in again
automatically after a short while. The thermo
switch can also trip after the tool is switched off. In
this case, after the tool is switched on again it
takes longer than usual until the temperature at the
blow-out opening is reached.
* does not apply to HE 20-600, H 16-500
2. The thermal fuse switches the tool off
completely in the event of overloading.
Short-term voltage drops
Switching on the machine reduces the voltage
briefly. Unfavourable mains power conditions may
have a detrimental effect on other machines.
Network impedances less than 0.4 ohms should
not cause malfunctions.

9 Accessories

Use only genuine Metabo accessories.
If you need any accessories, check with your
dealer.
For dealers to select the correct accessory, they
need to know the exact model designation of your
power tool.
For possible accessories, refer to the illustrations
on page 3.
A Flat spray nozzle
Drying, removal of old paint coats
B Spray nozzle
Removal of paint coats on window frames
C Reflector nozzle
Heating of plastics prior to forming; shrink
fitting of shrinking hoses
2011-1-30 13:31:25