Brush Cleaning; Tank And Vacuum Grid Cleaning; Vacuum System Motor Filter And Gasket Cleaning - Nilfisk-Advance SC350 Instructions For Use Manual

Hide thumbs Also See for SC350:
Table of Contents

Advertisement

Available languages

Available languages

ENGLISH

BRUSH CLEANING

NOTE
It is advisable to wear protective gloves when cleaning the brush because there may be sharp debris.
1.
Remove the brush, as shown in Use chapter.
2.
Clean and wash the brush with water and detergent.
3.
Check the brush bristles for integrity and wear; if necessary, replace the brush.

TANK AND VACUUM GRID CLEANING

1.
Drive the machine to the appointed disposal area.
2.
Turn the knob (32) to "0" and disconnect the battery.
3.
Lift the cover (A, Fig. 6), then clean and wash the cover
and the vacuum grid (B) with clean water. Drain the water
from the tanks (C and D) and clean them.
4.
If necessary, disengage the grid (B) by turning it and
remove the fl oat (E), than clean with care and reinstall.
5.
Check the recovery tank cover gasket (F) for integrity.
NOTE
The gasket (F) creates vacuum in the tank that is
necessary for vacuuming the recovery water.
If necessary replace the gasket (F) by removing it from
its housing (G) on the cover. When assembling the new
gasket, install the joint (H) in the area shown in the fi gure.
6.
Check that the seating surface (I) of the gasket (F) is
integral and adequate for the gasket itself.
If necessary, remove the screws (J), open the cover (K) and
check the gasket (L) for integrity, then clean with care and
reinstall.
7.
Close the recovery tank cover (A).
VACUUM SYSTEM MOTOR FILTER AND
GASKET CLEANING
NOTE
The gaskets (M and O) create vacuum in the system
that is necessary for vacuuming the recovery water.
1.
Drive the machine on a level fl oor.
2.
Turn the knob (32) to "0" and disconnect the battery.
3.
Open the cover (A, Fig. 6) and check the vacuum system
motor gasket (M) for integrity.
If necessary replace the gasket by removing it from its
housing.
4.
Check that the pre-fi lter (N) is clean. If necessary clean it
with water and compressed air, then install it.
5.
Lift the recovery tank (B) and check the gaskets (O) for
integrity.
If necessary replace the gasket by removing it from its
housing.
6.
Clean with care and reinstall.
16
INSTRUCTIONS FOR USE
9099122000(1)2011-01
K
J
A
H
C
I
O
SC350
G
E
F
B
N
I
Figure 6
L
M
D
P100412