All DIP switches are set to on by default, i.e. the video inputs are terminated with
75 Ohm.
If the signals are to be looped through the DIP switches must be set to off.
Malfunctioning of the SISTORE due to lack of termination
IMPORTANT
If the lines are not terminated correctly the image quality may deteriorate.
Termination should always be made at the end of the line.
1 to 8 (75 Ohm termination)
1
75 Ohm termination
Dipsw
Assignment
1
VIN13
2
VIN14
3
VIN15
4
VIN16
2
75 Ohm termination
Dipsw
Assignment
1
VIN29
2
VIN30
3
VIN31
4
VIN32
3
75 Ohm termination
Dipsw
Assignment
1
VIN9
2
VIN10
3
VIN11
4
VIN12