Setting Dip Switches (Sistore Mx / Mx Dvd) - Siemens SISTORE MX Installation Manual

Hybrid video recorder
Hide thumbs Also See for SISTORE MX:
Table of Contents

Advertisement

Installation
8.3

Setting DIP switches (SISTORE MX / MX DVD)

26
Siemens Building Technologies
Fire Safety & Security Products
Fig. 11
DIP switches
All DIP switches are set to on by default, i.e. the video inputs are terminated with
75 Ohm.
If the signals are to be looped through the DIP switches must be set to off.
Malfunctioning of the SISTORE due to lack of termination
IMPORTANT
If the lines are not terminated correctly the image quality may deteriorate.
Termination should always be made at the end of the line.
1 to 8 (75 Ohm termination)
1
75 Ohm termination
Dipsw
Assignment
1
VIN13
2
VIN14
3
VIN15
4
VIN16
2
75 Ohm termination
Dipsw
Assignment
1
VIN29
2
VIN30
3
VIN31
4
VIN32
3
75 Ohm termination
Dipsw
Assignment
1
VIN9
2
VIN10
3
VIN11
4
VIN12
02.2009

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sistore mx 3gSistore mx 3g dvd

Table of Contents