Application Information
B. Outdoor unit orifi ce pipe installation (where installation space is limited)
If the orifi ce pipe cannot be connected directly to the liquid valve due to space constraint, it can be connected
in between of the liquid pipe.
Steps:
1. Flare the liquid pipe and connect it to the liquid
valve.
2. Braze an additional "Male" joint to the liquid pipe.
Liquid Pipe
C. Indoor unit orifi ce pipe installation
Steps:
1. Braze an additional "Male" joint
to the liquid pipe.
Liquid Pipe
11
Brazer
Indoor Unit
2. Connect the "Female" nut of the
Orifi ce pipe to the"Male" joint.
Liquid Pipe
Brazer
Step 4
Orifice Pipe
Step 3
Step 2
Step 1
3. Connect the "Female" nut of the Orifi ce pipe to
the"Male" joint.
Liquid Pipe
4. Flare another liquid pipe and connect it to the
"Male" joint of the orifi ce pipe.
Liquid Pipe
Orifice Pipe
3. Flare another liquid pipe and
connect it to the "Male" joint of
the orifi ce pipe.
Orifice Pipe
Liquid Pipe
Orifice Pipe
Orifice Pipe
Orifice Pipe