Framing & Finishing; Gas Specifications; Gas Inlet & Manifold Pressures; High Elevations - Majestic NVBR36 Installation And Operating Manual

Table of Contents

Advertisement

Be sure to always maintain the proper one
(1) inch distance to combustibles around
B-vent pipe sections.
NOTE: Insulating for cold climates is strictly a recom-
mendation and not a requirement.
Framing and Finishing
Check appliance to make sure it is levelled
and properly positioned.
The appliance should only be mounted on the following sur-
faces:
• A flat combustible (burnable) surface.
• A raised wooden platform.
• A concrete block or other solid object
placed beneath each of the four corners
of the appliance.
To mount the appliance:
1. Choose unit location.
2. Four (4) nailing flanges are supplied with the fireplace
(found on the fireplace hearth). To level the box and secure
it firmly in place, remove the nailing flanges from the hearth
and install at the sides of the fireplace as shown in Figure 6.
f i r e - p a r t s . c o m
Fig. 6 Adjustable drywall strip (nailing flange).
Finishing
CAUTION: All joints between the finished
wall and the appliance surround (top and
sides) may be sealed only with non-com-
bustible material. Only noncombustible
material can be applied as facing to the ap-
pliance surround (the black painted face).
When finishing the appliance, never obstruct or modify
the air inlet/outlet grilles in any manner.
Finish the wall with the material of your choice. Refer to
Figures 5a and 5b for specific clearances when install-
ing a combustible mantel or other combustible projec-
tion.
Units: F34AR0, F34BR0, F34HR0, F34AC0, F34BC0,
F34HC0, G34AR0, G34BR0, G34HR0, G34AC0,
G34HC0
7412950
Nail Top
Standoffs
Nail Side-
Nailing
Flanges
FP549
FP549
9/29/97
BR/BC
NVB Series B-Vent Gas Fireplace
Gas Specification
Model
Fuel
Gas Control
NVBR36RN Natural
Millivolt Hi/Lo
NVBC36RN Natural
Millivolt Hi/Lo
NVBR36RP Propane
Millivolt Hi/Lo
NVBC36RP Propane
Millivolt Hi/Lo
NVBR36EN Natural Electronic Ignition 30,000 21,500
NVBC36EN Natural Electronic Ignition 30,000 21,500
NVBR36EP Propane Electronic Ignition 30,000 22,000
NVBC36EP Propane Electronic Ignition 30,000 22,000
NVBR42RN Natural
Millivolt Hi/Lo
NVBC42RN Natural
Millivolt Hi/Lo
NVBR42RP Propane
MIllivolt Hi/Lo
NVBC42RP Propane
Millivolt Hi/Lo
NVBR42EN Natural Electronic Ignition 30,000 21,500
NVBC42EN Natural Electronic Ignition 30,000 21,500
NVBR42EP Propane Electronic Ignition 30,000 22,000
NVBC42EP Propane Electronic Ignition 30,000 22,000
Air Shutter
Model
NVBR36RN, NVBC36RN,
NVBR36EN, NVBC36EN
NVBR42RN, NVBC42RN,
NVBR42EN, NVBC42EN
NVBR36RP, NVBC36RP,
NVBR36EP, NVBC36EP
NVBR42RP, NVBC42RP,
NVBR42EP, NVBC42EP
Gas Inlet & Manifold Pressures
Minimum Inlet Pressure
Maximum Inlet Pressure
Manifold Pressure
NVBR36 / NVBC36 / NVBC42 / NVBR42
Certified to
ANSI Z21.50b-2002 / CSA 2.22b-2002
Vented Gas Fireplace

High Elevations

Input ratings are shown in BTU per hour and are
certified without deration for elevations up to
4,500 feet (1,370m) above sea level.
For elevations above 4,500 feet (1,370m) in USA,
installations must be in accordance with the
current ANSI Z223.1/NFPA 54 and/or local codes
having jurisdiction.
In Canada, please consult provincial and/or local
authorities having jurisdiction for installations at
elevations above 4,500 feet (1,370m).
Max.
Min.
Input
Input
30,000 21,500
30,000 21,500
30,000 22,000
30,000 22,000
30,000 21,500
30,000 21,500
30,000 21,500
30,000 21,500
Gap
8 mm
10 mm
2 mm
2 mm
Natural
LP
5.5" w.c.
11.0" w.c.
14.0" w.c.
14.0" w.c.
3.5"w.c.
10.0" w.c.
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nvbc36Nvbr42Nvbc42

Table of Contents