Clearance To Combustibles; Mantels; Hearths; Framing And Finishing - Majestic DBT33 Installation Instructions & Homeowner's Manual

Top vent direct vent models
Table of Contents

Advertisement

C
LEARANCE TO
Appliance
Top............................. 0 mm (0")
Bottom....................... 0 mm (0")
Side............................ 0 mm (0")
Back........................... 0 mm (0")
Venting
Concentric sections of DV Vent
Top, bottom & sides .. 25 mm (1")
M
The height that a combustible mantel is fitted above the fire-
place is dependent on the depth of the mantel. This also applies
to the distance between the mantel leg (if fitted) and the
fireplace.
For the correct mounting height and widths refer to Fig. 2 and
the following Mantel Charts.
The fitting of a bay window trim kit does not effect the
distances and reference points referred to in the diagram and
chart.
Non-combustible mantels and legs may be installed at any
height and width around the appliance.
When using paint or lacquer to finish the mantel, such paint or
lacquer must be heat resistant to prevent discolouration.
10002789/0
C
OMBUSTIBLES
ANTELS
A Hearth is not mandatory but it is recommended for aesthetic
purpose. We recommend a non-combustible hearth which
projects out 12" (305 mm) or more from the front of the
fireplace.
Cold climate Installation Recommendation:
1.
Choose the unit location.
2.
Place the unit into position and secure it to the floor with
1.5" (38 mm) screws, or nails. The holes to secure the
unit to the floor are located just behind the access door
grille on the left and right side of the unit.
3.
Frame in the fireplace with a header across the top. It is
important to allow for the finished wall face when setting
the depth of the frame.
4.
Attach the fireplace to the frame using the adjustable
frame drywall strips (located behind the access door for
shipping). Preset the depth to suit the facing material of
the wall. The strips are adjustable to 1/2"(13 mm), 5/8"
(16 mm) or 3/4" (19 mm), Fig. 3 & 4.
5.
Screw through the slotted holes in the drywall strip and
into the pre-drilled holes in the fireplace side. Measure
from the face of the fireplace to the face of the drywall
strip to confirm the final depth.
Fig. 2
-5-
H
EARTH
When installing this unit against a non-insu-
lated exterior wall or chase, it is mandatory that
the outer walls be insulated to conform to appli-
cable insulation codes.
F
F
RAMING AND
DBT33/DBT36/DBT39
INISHING