INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
WARNING:
If the information in these
instructions is not followed exactly, a re or
explosion may result causing property damage,
personal injury or death.
FOR YOUR SAFETY
Installation and service must be performed
by a quali ed installer, service agency or the
gas supplier.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from
a neighbour's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier call
the re department.
Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any
other appliance.
This appliance may be installed in an aftermarket
permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certi ed kit is used.
This appliance is suitable for installation in a
bedroom or bed sitting room.
030615-40
SERIAL #
TC54
INSTALLATION
AND OPERATING
INSTRUCTIONS
MODEL
TC54
SERIES D
MODULAR DIRECT VENT
FIREPLACE
TC54_D
5056.42562

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TC54 SERIES DMODULAR and is the answer not in the manual?

Questions and answers

Summary of Contents for Town & Country Fireplaces TC54 SERIES DMODULAR

  • Page 1 INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. WARNING: If the information in these instructions is not followed exactly, a re or explosion may result causing property damage, personal injury or death. FOR YOUR SAFETY Installation and service must be performed by a quali ed installer, service agency or the SERIAL #...
  • Page 2: Table Of Contents

    Table of Contents Table of Contents Caution ..............3 Gas Pressure Check ..........17 Safety ..............3 Horizontal Termination Venting ......18 Important Note for the Vertical Termination Venting ......... 18 Commonwealth of Massachusetts ......4 Roof Termination Venting Chart ......19 Fireplace Dimensions ..........
  • Page 3: Caution

    Caution FOR YOUR SAFETY - Do not install or operate your Town & Country replace without rst reading and understanding this manual. Any installation or operational deviation from the following instructions voids the Town & Country Fireplaces Warranty and may prove hazardous.
  • Page 4: Important Note For The Commonwealth Of Massachusetts

    Important Note for the Commonwealth of Massachusetts: From Massachusetts Rules and Regulations 248 CMR 5.08: For all side wall horizontally vented gas fuelled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above nished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satis ed.
  • Page 5: Fireplace Dimensions

    Fireplace Dimensions Fig. #1 3 5/8" 62 9/16" 35 5/8" 63 7/8" 44 1/2" 48 1/8" 44 1/2" 34 1/8" 34 13/16" 54 5/16" Minimum Clearances to Combustible Material Fig. #2 NON-COMBUSTIBLE ZONE. STEEL FRAMING COMBUSTIBLE FRAMING AND DO NOT INSTALL ANY COMBUSTIBLE MATERI- FINISH WALL ABOVE STANDOFFS AL, ELECTRICAL WIRING OR GAS PLUMBING IN STANDOFFS...
  • Page 6: Installation Requirements

    Fig. #4 Installation Requirements The Town & Country Fireplace installation and venting must conform to the current CAN/CGA-B149 installation code (in Canada) or the current National Fuel Gas Code, ANSI Z223.1 (in the USA), and approved per local codes. Only quali ed (licensed or trained) personnel should install this product.
  • Page 7: Top Standoffs

    Top Standoffs The top standoffs are shipped loose inside Fig. #8 the replace and must be installed on top of the replace as shown in Fig #8. Do this once the replace is on site and in position. Locating The Fireplace In planning the installation for the replace, it is necessary to determine where the unit is to be installed, location of vent system and where gas supply piping may be plumbed.
  • Page 8: Framing And Finishing

    Framing and Finishing Note: The replace should be in place Chase Insulation: position. Secure the steel frame to the framing When installing this and venting installed before framing in brackets on each side of the unit. Ensure that replace against a non-insulated exterior wall or building an enclosure around the unit.
  • Page 9 Fig. #11 Fig. #11a IF FINISHING THE WALL ABOVE THE UNIT NON-COMBUSTIBLE BOARD DETAIL WITH PAINT, THE FRAMING KIT SHIPPED WITH THE UNIT SHOULD BE DISCARDED. U S E F U L L S H E E T S O F CA L C I U M SILICATE BOARD OR EQUIVALENT AND FULL LENGTH METAL STUDS TO FINISH AND FRAME AROUND THE UNIT.
  • Page 10: Steel Stud Framing Kit

    Steel Stud Framing Kit TC54.FRKT Fig. #14 Each Kit Contains: Item Description Qty. Item Description Qty. SCREW, TEKS #8 x 1/2 STUD, HEADER HORIZONTAL (Not shown) 58 1/4" L STUD, INNER SIDES STUD PLATE, HORIZONTAL 63 3/4”L STUD, OUTER SIDES BASE PLATE 5 15/16”...
  • Page 11 5. Install Non-combustible Board 1. Top Frame Assembly 4. Secure to Existing Framing • • Use drywall screws to install the • Lay out the horizontal header Secure the frame assembly to existing concrete board (Fig #16). stud (5) on a large flat surface.
  • Page 12: Adjustable Lintel

    Adjustable Lintel The adjustable lintel assembly has Fig. #17 two orientations for desired nishing. A anged edge and a hemmed edge. The lintel comes factory installed with the ange edge out. If the desired edge is different from the factory setting, use the following steps to change the screen.
  • Page 13: Hearth Extension

    Fig. #19 This replace recessed up to a maximum depth Non combustible building 4½” from screen, this material may not extend Area inside Lintel must recess must be constructed from past this point remain free of obstructions non-combustible material. The space between the outside lintels and the rebox must be completely free of any debris and the window with trim...
  • Page 14: Electrical

    Electrical The gas control system is located on the right hand side of the rebox behind an access FIREBOX ACCESS PANEL panel and the decorative rebox panel (if installed). The replace is operated via a wall control and a hand held remote control unit. Fig.
  • Page 15: Wall Switch And Remote Control

    Wall Switch and Remote Control Fig. #25 Fig. #26 Fig. #24 TO FIREPLACE Insert a straightened paper clip into Press the ON/OFF button of the Linking the remote control unit to the the “PROGRAM” slot on the wall remote unit. Once the wall unit beeps wall switch.
  • Page 16: Home Automation

    Home Automation The home automation feature supplied with this replace is capable Fig. #28 of controlling the ame and light on/off function with the use of a dry contact relay common to home automation systems. Furthermore, the ame and light level may be modulated from high to low using the 0 - 10 volt analog output available on most home automation systems.
  • Page 17: Gas Supply

    Gas Supply Caution: The gas line should be installed by a quali ed service person in accordance with all building codes. This section is intended as a guide for quali ed technicians installing this appliance. Consult local and / or national building codes before proceeding. •...
  • Page 18: Horizontal Termination Venting

    Horizontal Termination Venting (Power Vented) This unit can be vented horizontally (wall termination) ONLY with an approved High Capacity Power Vent Kit (TCVT.PVAX2) using TC 8x11 Vent Pipe. Please use the in- structions provided with the optional High Capacity Power Vent Kit when planning any installation where a horizontal termination is required.
  • Page 19: Roof Termination Venting Chart

    Roof Termination Venting Chart Various combinations of vent runs may be Fig. #32 used. Refer to Fig for details. For optimum MAX. performance and ame appearance, keep the vent length to a minimum. Connections between each vent system component must be tightly joined, secured with sheet metal screws and sealed.
  • Page 20 Ceiling Opening: Fig. #33 Determine the exact position of the replace so that the vent pipe is centred (if possible) between two building framing members. Lay out the vent system path, 14 1/2” minimizing the number of elbows and length of vent. Consult your local building codes prior to proceeding.
  • Page 21 Roof Vent Terminal: 1. Place the roof ashing over the vent pipe, secure and seal it to the roof using the methods and materials appropriate for the type of roof on the building. Shingle roof example shown (Fig #35) 2. Place the storm collar down over the vent pipe until it is level. Tighten storm collar for a snug t.
  • Page 22: Vent Terminal Clearance

    Vent Terminal Clearance Minimum clearances to the vent terminal must be maintained as VENT TERMINAL MINIMUM CLEARANCES Fig. #36 shown in gure #36 & 37. Measure clearances to the nearest edge of TO ADJACENT STRUCTURES termination hood. NOTE: Vent terminal must not be recessed NOTE: LOCAL CODES OR REGULATIONS MAY REQUIRE DIFFERENT CLEARANCES.
  • Page 23: Vent Restrictor Adjustment

    Vent Restrictor Adjustment The vent restrictor is located on the underside of the rebox top. The unit leaves the factory Fig. #38 with the vent restrictor wide open. The restrictor is built into the appliance for secondary air WALL AND ROOF ow adjustment.
  • Page 24: Roof Termination Kit

    Roof Termination Kit TCVT.RTA Fig. #40 VERTICAL TERMINATION CAP TCVT.9365 STORM COLLAR TC42.90665 CEILING FIRESTOP TCVT.THIMA ROOF SUPPORT BRACKET TCVT.93915 TC54_D 030615-40 5056.42562...
  • Page 25: Vent Pipe Dimensions

    Vent Pipe Dimensions Fig.#41 11” 12" PIPE ....10 1/4" 18" PIPE ....16 1/4" 24" PIPE ....22 1/4" 48" PIPE ....46 1/4" 10 15/16" 9 1/2" TCVT.8 11X12ADJ 11 1/8" TCVT.8 11X _ _ 12 9/16" 13 1/8" TCVT.8 11XLB45 Vent Offset Chart Fig.
  • Page 26: Firebox Panels Installation

    Firebox Panels Installation TC54 PANELS PARK AVE. BEIGE HERRINGBONE2 ..........TCPN.54PAC2 MOUNT VERNON RED BRICK2 ..........TCPN.54VRC2 MANHATTAN STACKED BRICK2 ..........TCPN.54MNC2 BLACK PORCELAIN ................TCPN.774.C COFFEE BEAN BROWN PORCELAIN ........TCPN.774CB.C COPPER PORCELAIN ..............TCPN.774CU TITANIUM PORCELAIN ..............TCPN.774TI MILAN LIGHT PLASTER ............TCPN.54MILC2 (See Porcelain panel instruction manual for speci c instructions for these panels) Fig.
  • Page 27: Finishing Touch Trim Kit Instructions

    Fig. #43d REAR LOWER (HERRINGBONE PANEL PANEL SET SHOWN) REAR UPPER PANEL RIGHT SIDE LEFT SIDE PANEL PANEL LEFT FRONT RIGHT FRONT PANEL PANEL Finishing Touch Trim Kit Instructions Fig. #44 Place two smaller magnets on back of each side rail.
  • Page 28: Lighting Instructions

    Lighting Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: - Immediately call your gas supplier from a neighbour's phone. Follow If you do not follow these instructions exactly, a the gas supplier's instructions. fire or explosion may result causing property damage, - If you cannot reach your gas supplier, call the fire department.
  • Page 29: First Fire

    First Fire When lit for the rst time, the replace will emit a slight odor for a couple of hours. This is due to the curing of paints, seal- ants and lubricants used in the manufacturing process. This condition is temporary. Open doors and windows to ventilate area.
  • Page 30 Fig. #46 Remote Control Transmitter LCD display. Note: Some functions may not be available Attention! • Turn off the main gas supply for the appliance during installation or maintenance of the receiver/module device. • Turn off main gas supply for the appliance prior to removing or reinserting the batteries.
  • Page 31 Fireplace Description The Pro ame2 Remote Control Fireplace consists of three elements: Pro ame2 Remote Control Transmitter. Pro ame Integrated Fireplace Control (IFC) board and a wiring harness to connect the IFC to the gas valve and stepper motor (Fig. 23, page 14). Wall mounted Remote Control Receiver (Figs.
  • Page 32 Program button Fig. #47 wall switch electronics Fig. #50 Remote Control Transmitter battery bay Fig. #49 Town & Country wall Fig. #48 wall switch batteries side switch face plate. Using the Remote Control Transmitter Temperature indication Display With the remote control transmitter in the “OFF” position, press the thermostat and mode keys at the same time.
  • Page 33 Remote Flame Control The Pro ame2 has six (6) ame levels. With the replace turned on, and the ame level at maximum height, press the down arrow key once (Fig. 53 Flame level 1) to reduce the ame height by one step until the ame is turned off.
  • Page 34 Remote dimmer control (Light) The auxiliary function controls the AUX power outlet by the dimmable light control. To activate this function use the Mode Key ( g. 45) to index to the light bulb icon ( g. 59). The inten- sity of the output can be adjusted through six (6) levels.
  • Page 35: Maintenance

    APPENDIX Maintenance CAUTION: Turn off gas and electrical power supply (if applicable) and allow ample time for unit to cool before servicing appliance. It is recommended that the replace and its venting should be inspected at least once a year by a quali ed service person. Glass Panel: Fig.
  • Page 36: Replacement Parts

    Replacement Parts PARK AVE. BEIGE HERRINGBONE2 ........TCPN.54PAC2 (WHEN ORDERING, INCLUDE PART NUMBER WITH DESCRIPTION) MOUNT VERNON RED BRICK2 .......... TCPN.54VRC2 ITEM DESCRIPTION PART NO. MANHATTAN STACKED BRICK2 .........TCPN.54MNC2 BLACK PORCELAIN ..............TCPN.774.C TC54 BODY ASSM ........TC54.CE COFFEE BEAN BROWN PORCELAIN ........TCPN.774CB.C GLASS ASSM........GLAS.2054ASSY COPPER PORCELAIN ............
  • Page 37: Replacement Parts - Control System

    Replacement Parts – Control System (WHEN ORDERING, INCLUDE PART NUMBER WITH DESCRIPTION) ITEM ..DESCRIPTION ..........PART NO. ITEM ..DESCRIPTION ..........PART NO. #1 ..CONTROL ASSEMBLY KIT ....TCCV.95755-B #4 ..TEST FITTING ..........5019.104 #2 ..BULKHEAD ASSEMBLY KIT .......TCRP.8133 #5..
  • Page 38: Wiring Diagram

    Wiring Diagram Fig. #66 TC54_D 030615-40 5056.42562...
  • Page 39: Rating Label

    Rating Label NOTE: The Rating Label is located on a plate found in a slot between the left hand side lintel and the left hand side window frame. This plate is attached to the lintel with a cable. VENTED GAS FIREPLACE - NOT FOR USE WITH SOLID FUEL FOYER AU GAZ À...
  • Page 40 © 2015 Copyright Paci c Energy Fireplace Products LTD Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. For technical support, please contact your retailer Web site: www.townandcountry replaces.net 2975 Allenby Rd., Duncan, BC V9L 6V8 Printed in Canada...