ICRealtime ICIPP3020HDIR Installation Manual

Ir speed dome

Advertisement

Quick Links

IR Speed Dome Installation Manual
Version 2.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ICIPP3020HDIR and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ICRealtime ICIPP3020HDIR

  • Page 1 IR Speed Dome Installation Manual Version 2.0...
  • Page 2: Table Of Contents

    Table of Contents IR SPEED DOME INSTALLATION ..............8 Installation Preparation ......................... 8 IR speed dome and network IR speed dome installation ..............9 Speed dome bracket installation ....................9 1.2.1 Pipe thread bracket installation....................... 9 1.2.2 Clip wall mount bracket installation ....................10 1.2.3 Address and Baud Rate Setup .....................
  • Page 3 Installation............................. 17 Installation Requirements ......................17 3.2.1 Installation Steps..........................17 3.2.2 HANG MOUNT BRACKET INSTALLATION ............. 19 Component Installation ........................19 Installation............................. 19 Installation Requirements ......................19 4.2.1 Installation Steps..........................19 4.2.2 CORNER MOUNT BRACKET INSTALLATION ..........21 Component Installation ........................21 Installation.............................
  • Page 4 The Problem in Practical Use ......................26 RS485 Bus FAQ ..........................27 APPENDIX Ⅲ THE RELATIONSHIP BETWEEN THE 24V AC CABLE DIAMETER AND THE TRANSMISSION DISTANCE..........28 10 APPENDIX IV WIRE GAUGE REFERENCE SHEET ........29...
  • Page 5 Welcome Thank you for purchasing our speed dome! Please read the following safeguards and warnings carefully before you install or use the product!
  • Page 6: Important Safeguards And Warnings

    Important Safeguards and Warnings Safety Measures Qualified Engineer Needed The installation engineer or maintenance engineer shall have corresponding CCTV system installation certificate or maintenance qualification certificate. The installation engineer or maintenance engineer shall have qualification certificate for work at height. The installation engineer or maintenance engineer shall have the basic knowledge and operation technique for low-voltage cable layout and low-voltage electronic cable connection.
  • Page 7 We are not liable for any problems caused by unauthorized modifications or attempted repair. Do not allow other object falling into the device Please make sure there is no metal or inflammable, explosive substance in the speed dome. The above mentioned objects in the device may result in fire, short-circuit or damage. Please shut down the device and disconnect the power cable if there is water or liquid falling into the camera.
  • Page 8: Ir Speed Dome Installation

    1 IR SPEED DOME INSTALLATION 1.1 Installation Preparation Basic Requirement All installation and operation here should conform to your local electrical safety codes. Before installation, please open the package and check all the components are included. Please make sure the speed dome installation environment and installation mode can meet your requirement.
  • Page 9: Ir Speed Dome And Network Ir Speed Dome Installation

    1.2 IR speed dome and network IR speed dome installation 1.2.1 Speed dome bracket installation The speed dome has several types of installation brackets. You can refer to the following contents for detailed information. Here we are going to install the IR speed dome in wall mount bracket.
  • Page 10: Clip Wall Mount Bracket Installation

    Figure 1-1 1.2.3 Clip wall mount bracket installation Please connect the flange to the speed dome device. Connect the cable port of the flange to the slot of the speed dome one by one (It includes power, video, RS485, network cable and alarm input/output.
  • Page 11: Install The Ir Speed Dome And Then Connect The Cable

    Figure 1-3 1.2.5 Install the IR speed dome and then connect the cable Hang the IR speed dome device to the flange. Please insert the cable socket to the corresponding slots according to the indication label. See Figure 1. Alarm input and output port 2.
  • Page 12: Secure The Speed Dome To The Flange

    1.2.6 Secure the speed dome to the flange Please check the rubber airproof ring of the speed dome adjacent to the flange is proper or not. Use the internal hex screwdriver to fix IR speed dome and the flange to complete the installation. See Figure 1-5.
  • Page 13: Communication Protocol And Baud Rate

    Figure 1-6 1.4.1 Communication protocol and Baud rate Please refer to the protocol sheets for detailed information. Ω Ω Protocol Baud rate Parity Connect to the 120 Communication Protocol DH-SD ( Compatible with China industrial standard protocol) PELCO-D PELCO-P Reserved Please refer to the baud rate sheet for detailed information.
  • Page 14: Address Setup

    NONE EVEN NONE 1.4.2 Address Setup The speed dome address setup interface is shown as below. See Figure 1-7. Figure 1-7 The encode mode adopts binary system. 1 to 8 is valid bit. The highest address bit is 255. You can refer to the following sheet for more information.
  • Page 15: Bracket Dimensions

    2 BRACKET DIMENSIONS 2.1 Wall mount bracket The wall mount bracket dimensions are shown as below. See Figure 2-1. 4-Ф9 Ф58 Figure 2-1 2.2 Hanging mount bracket (Multiple Lengths) The hanging mount bracket is shown as below. See Figure 2-2. The bracket length setup values are:...
  • Page 16: Corner Mount Bracket

    2.3 Corner mount bracket The corner mount bracket is shown as below. See Figure 2-3. Figure 2-3 2.4 Pole mount bracket The corner mount bracket is shown as below. See Figure 2-4. Figure 2-4...
  • Page 17: Wall Mount Bracket Installation

    3 WALL MOUNT BRACKET INSTALLATION 3.1 Component Installation Wall mount bracket and its components are shown as below. See Figure 3-1. Figure 3-1 3.2 Installation 3.2.1 Installation Requirements The wall mount speed dome can be installed in the hard construction wall in the indoor or outdoor environments.
  • Page 18 Figure 3-3 Please refer to chapter 1.2 for detailed installation information.
  • Page 19: Hang Mount Bracket Installation

    4 HANG MOUNT BRACKET INSTALLATION 4.1 Component Installation Hang mount bracket and its components are shown as below. See Figure 4-1. Figure 4-1 4.2 Installation 4.2.1 Installation Requirements The hang mount speed dome can be installed in the hard construction wall in the indoor or outdoor environments.
  • Page 20 Pull the cable through the steeve and then secure the steeve to the flange. Fix the M4 bolt. Please note, if the speed dome is installed in the outdoor environments, you need to paste enough Teflon tape at the top screw thread of the steeve and then turn the steeve to the flange firmly.
  • Page 21: Corner Mount Bracket Installation

    5 CORNER MOUNT BRACKET INSTALLATION 5.1 Component Installation Corner mount bracket and its components are shown as below. See Figure 5-1. Figure 5-1 5.2 Installation 5.2.1 Installation Requirements The corner mount speed dome can be installed in the hard construction wall in the indoor or outdoor environments where there is a 90 degrees angle.
  • Page 22 Figure 5-3 Please refer to chapter 1.2 for detailed installation information.
  • Page 23: Pole Mount Bracket Installation

    6 POLE MOUNT BRACKET INSTALLATION Pole mount bracket and its components are shown as below. See Figure 6-1. Figure 6-1 6.1 Installation 6.1.1 Installation Requirements The corner mount speed dome can be installed in the hard construction wall in the indoor or outdoor environments.
  • Page 24 Clamp and pole bracket connection Pole bracket and the pole connection Figure 6-3 After you installed bracket and external cover, loosen the captive screws and open the panel, pull the power cable through the hanging bracket and then fix the hanging bracket to the wall. Please pay attention to the waterproof between the bracket and the wall.
  • Page 25: Appendix Ⅰ Thunder Proof And Surge Protection

    7 APPENDIX Ⅰ THUNDER PROOF AND SURGE PROTECTION This series speed dome adopts TVS lighting protection technology. It can effectively prevent damages from various pulse signals below 1500W, such as sudden lighting and surge. While maintaining your local electrical safety code, you still need to take necessary precaution measures when installing the speed dome in the outdoor environment.
  • Page 26: Appendix Ⅱ About Rs485 Bus

    8 APPENDIX Ⅱ ABOUT RS485 BUS 8.1 RS485 Bus Main Feature RS485 is semi duplex communication cable of impedance 120Ω. Its max load amount is 32 effective loads (including main control device and devices to be charged). 8.2 RS485 Bus Transmission Distance When we take 0.56mm (24AWG) twisted-pair as communication cable, the max transmission distance (theoretically) are listed below (according to different baud rates).
  • Page 27: Rs485 Bus Faq

    Figure 8-2 8.4 RS485 Bus FAQ Phenomenon Possible Reasons Solution Modify host or speed dome setup ; Speed dome Host address(baud rate) and can run self- speed dome address(baud rate) Switch RS485 positive end and diagnosis but I are not match; negative end;...
  • Page 28: Appendix Ⅲ The Relationship Between The 24V Ac Cable

    9 Appendix Ⅲ The relationship between the 24V AC cable diameter and the transmission distance It is the recommended transmission distance when the cable diameter is fixed and the 24V AC power consumption is below 10%. For the AC device, the max permission voltage power consumption is 10%.
  • Page 29: Appendix Iv Wire Gauge Reference Sheet

    10 Appendix IV Wire gauge reference sheet Metric bare wire Bare wire cross diameter section (mm) (mm ) 0.050 0.00196 0.060 0.00283 0.070 0.00385 0.080 0.00503 0.090 0.00636 0.100 0.00785 0.110 0.00950 0.130 0.01327 0.140 0.01539 0.160 0.02011 0.180 0.02545 0.200 0.03142 0.230...

Table of Contents