Summary of Contents for ICRealtime ICIP-D2000-IR-B
Page 1
HD IR Waterproof Network Dome Camera User’s Manual Version 3.5.1...
Page 2
Welcome Thank you for purchasing our Network camera! This user’s manual is designed to be a reference tool for your system. Please read the following safeguard and warnings carefully before you use this series product! Please keep this user’s manual well for future reference!
Page 3
Important Safeguards and Warnings 1.Electrical safety All installation and operation here should conform to your local electrical safety codes. The power shall conform to the requirement in the SELV (Safety Extra Low Voltage) and the Limited power source is rated 12V DC in the IEC60950-1.This series product supports PoE too. Please note: Do not connect these two power supplying sources to the device at the same time;...
Page 4
Do not touch the CCD (CMOS) optic component. You can use the blower to clean the dust on the lens surface. Always use the dry soft cloth to clean the device. If there is too much dust, please use the water to dilute the mild detergent first and then use it to clean the device.
1 General Introduction 1.1 Overview This series network camera integrates the traditional camera and network video technology. It adopts video data collection, transmission together. It can connect to the network directly without any auxiliary device. This series network camera uses standard H.264 video compression technology, which maximally guarantees the video quality.
1.3 Specifications Please refer to the following sheet for network camera performance specification. Model ICIP D2000IR Parameter Main Processor TI Davinci high performance DSP Embedded LINUX System Support real-time network, local record, and remote operation at the Resources same time. User Interface Remote operation interface such as WEB, DSS, PSS System Status...
Page 9
Default Setup Setup Item ICIP D2000IR Bit Rate 8192 I Frame interval Watermark Enable Watermark DigitalCCTV character Enable Enable Bit stream General type Encode H.264B mode Resolution CIF(352*288) PAL: 25 Frame Rate(FPS) NTSC:30 Stream Bit Rate Type Recommend 192-1024Kb/S ed Bit Bit Rate 1024 I Frame...
Page 10
Default Setup Setup Item ICIP D2000IR Preferred 8.8.8.8 Alternate 8.8.8.8 Enable ARP/Ping set Enable device address service Connection TCP Port 37777 UDP Port 37778 Connection HTTP Port RTSP Port Enable HTTP Disable HTTPs Port Enable Disable PPPoE Username none Password Server Type Disable,CN99 DDNS Server IP...
Page 11
Default Setup Setup Item ICIP D2000IR Attachment Mail Receiver 0 seconds Email Test Disable,interval=60 seconds UPnP Enable UPnP Disable SNMP Port Read public Community Write private Community SNMP Trap Address Trap Port SNMP v1:Disable SNMP Version SNMP v2:Disable SNMP v3:Disable Enable Enable Bonjour...
Page 12
Default Setup Setup Item ICIP D2000IR Remote path share Emergency Disable (Local) Pack Duration 8 minutes Pre-record 5 seconds Disk Full Overwrite Record Mode Auto Bit Stream Main Stream Device No Device MAC address Language English Local Host Video PAL/NTSC Standard Date Format Y-M-D...
2 Structure 2.1 Components You can refer to the following figure for multiple-function combination cable information. See Figure Figure 2-1 Please refer to the following sheet for detailed information. Component Component Name Component 1 Device lens Component 2 Dome body Component 3 Dome enclosure Port...
Page 14
Please refer to the following two figures for dimension information. The unit is mm. See Figure 2-2 and Figure 2-3. Figure 2-2 Figure 2-3...
3 Device Installation 3.1 Installation Steps Important Before the installation, please make sure the installation environments can at least support 3x weight of the camera. Please follow the steps listed below to install the device. Please refer to Figure 3-1 for reference. Step 1 Turn clockwise to remove the decoration ring from the snap joints.
Page 16
Figure 3-2 Note This series product supports two cable exits. One is from the bottom and the other is from the side. Please refer to the following figure for cable exit from the side information. Figure 3-3 Please earth the GND port of the device to enhance the device reliability. The GND port is near the cable exit port on the rear of the dome.
Figure 3-4 3.2 Restore Factory Default Setup Introduction Important Please use RESET button when device is running. Step1 Please refer to step1 and step2 in chapter 3.1to loose the dome body. Push a little bit; you can take the dome body from the gland cover. Step2 Take the dome body out and then turn the top cover hard to remove.
4 Quick Configuration Tool 4.1 Overview Quick configuration tool can search current IP address, modify IP address. At the same time, you can use it to upgrade the device. Please note the tool only applies to the IP addresses in the same segment. 4.2 Operation Double click the “ConfigTools.exe”icon, you can see an interface is shown as in Figure 4-1.
Page 19
In the configuration tool search interface (Figure 4-1), please select a device IP address and then double click it to open the login interface. Or you can select an IP address and then click the Login button to go to the login interface. See Figure 4-3. In Figure 4-3, you can view device IP address, user name, password and port.
5 Web Operation This series network camera product supports the Web access and management via PC. Web includes several modules: monitor channel preview, system configuration, alarm and etc. 5.1 Network Connection Please follow the steps listed below for network connection. ...
Page 21
Figure 5-2 If it is your first time to login in, system pops up warning information to ask you whether install control webrec.cab or not after you logged in for one minute. Please click OK button, system can automatically install the control. When system is upgrading, it can overwrite the previous Web too. If you can’t download the ActiveX file, please check whether you have installed the plug-in to disable the control download.
6 FAQ I can not boot up Please click RESET button for at least five seconds to restore factory default setup. the device or operate properly. The water leakage The unauthorized front or rear cap remove many result in water occurred.
Appendix Toxic or Hazardous Materials or Elements Toxic or Hazardous Materials or Elements Component Name Cr VI PBDE Circuit Board ○ ○ ○ ○ ○ ○ Component ○ ○ ○ ○ ○ ○ Device Case ○ ○ ○ ○ ○ ○...
Need help?
Do you have a question about the ICIP-D2000-IR-B and is the answer not in the manual?
Questions and answers