MAINTENANCE
18.5

Silencer

24cxi / 30cxi
2
B
1
A
Key
1
Silencer retaining screw
2
fixed silencer
3
Removable silencer
• Remove the silencer retaining screws (1) and remove the
silencer (3).
• Clean the interior of the silencer with a dry cloth if necessary,
taking care not to damage the internal foam.
• Repeat the operation in reverse order to replace the silencer.
35cxi
3
A
2
1
- 42 -
Supplied By www.heating spares.co Tel. 0161 620 6677
3
C
Key
1
fixed silencer
2
Silencer retaining clip
3
Removable silencer
• Unclip and remove the silencer (3).
• Clean the interior of the silencer with a dry cloth if necessary,
taking care not to damage the internal foam.
• Repeat the operation in reverse order to replace the silencer.
18.6

Expansion vessel

2
1
Key
1
Expansion vessel
2
Expansion vessel pressure inlet
• Check the expansion vessel's supply pressure (see «
Technical Data » chapter) by means of the pressure inlet
located on the expansion vessel. Adjust the pressure if
necessary.
• Following the installation of a new expansion vessel, fill and
purge the appliance or installation, if necessary.
0020085231_02 - 05/10 - Glow-worm

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ultracom 2 24cxi and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Ultracom 2 30cxiUltracom 2 35cxi

Table of Contents

Save PDF