Lamp Abnormality - Sanyo PLC-XF47 Service Manual

Multimedia
Hide thumbs Also See for PLC-XF47:
Table of Contents

Advertisement

Troubleshooting

Lamp Abnormality

■ The Lamp Driving Circuit (
LAMP COVER
THERMAL SWITCHES
SW
K26Z
K26U
FANNET_2
ASS'Y
EXH FANNET
K56A
3
1
K8U
12VA
ASS'Y MAIN
NOTE :
■ At first, the high-voltage pulse (about 8KVp-p) is generated between the lamp
electrodes to generate glow discharge. Then dielectric breakdown occurs,
finally glow discharge comes to arc discharge.
■ After projector turned on, 30 seconds are required until the light output
stabilizes.
■ After the projector is turned off, the cooling fans operate for 90 seconds to cool
down the lamp and reduce gas pressure inside the lamp.
NOTE :
Switch
Lamp Cover
Make sure that the lamp cover is mounted correctly. If not or the lamp cover
removed, the lamp does not light for safety.
Check the boss of the lamp cover and the lamp cover switch (SW902).
SW902 -- open : Abnormality
■ Temperature Switches
When the internal temperature near the lamps reaches near 120ºC, the
temperature switches open and 12V_PFC is not supplied to PFC-Unit.
SW903 - SW906 -- open : Abnormality
■ READY (green) LED indicates lamp monitor operation
LED off:
Lamp is being cooled.
LED on:
Lamp is being lit or already cooled down.
Lamp_3 )
example
AC INPUT
K26T
AC85~264V
12V_FN
P_FAIL
GND
3
P_FAIL_FAN
K8Q
5
12V_FAN_C
4
12V_PFC
6
PFC_ON/OFF_CN3
7
PFC_ON/OFF_CN4
1
P_FAIL_CN3
2
P_FAIL_CN4
8
GND
DC INPUT
DC380~400V
1
LAMP_RX
2
GND
3
S5V
4
BALLAST SW
5
LAMP_TX
UNIT_PFC3-4
LINE
FILTER
CN5
1
2
H : Abnormality
3
CN6
3
5
4
6
H : ON
7
H : ON
1
L : Abnormality
2
8
L : Abnormality
UNIT_LAMP BALLAST
FILTER
DOWN
BUFFER
CONVERTER
CJ2
1
H : Abnormality
2
3
H : ON
4
5
■ When the temperature
around a lamp driver
reaches 85 degrees,
unit lamp ballast will
be shut down and a
lamp monitor signal
changes from L to H .
■ The CPU performs an input check by the lamp monitor
pin.
■ When the "H" signal continues 1 second or more con-
tinuously, the CPU judges the state to be abnormal.
■ When it has detected abnormal condition, the CPU
turns off a projector compulsorily. And the CPU sets up
the cooling time for 90 seconds.
■ The projector cannot be turned on during a cooling
time.
- 70 -
BRIDGE
ACTIVE
DIODE
FILTER
THERMAL
PROTECTOR
BRIDGE
ACTIVE
DIODE
FILTER
THERMAL
PROTECTOR
P_FAIL
DETECTOR
P_FAIL
DETECTOR
PRIMARY CIRCUIT
FULL
IGNITION
BRIDGE
CIRCUIT
Output voltage.
No load Voltage Range : DC180 ~ 210V
At Lamp Lighting stability Range: AC 77 ~ 150V
CONTROL
Output Power.
Rated Power Range
Reduced Power Range : 264 ~325.6 9W
■ When the output volt-
age reaches abnormal
voltage (exceeds AC
130V), unit lamp ballast
will be shut down and
a lamp monitor signal
changes from L to H.
CPU : ---- Lamp monitor operation ----
DC OUTPUT
DC380~400V
DC OUTPUT
DC380~400V
LAMP
ASS'Y_3
+
: 330
9W
-
+
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents