Sanyo PLC-XF47 Service Manual page 67

Multimedia
Hide thumbs Also See for PLC-XF47:
Table of Contents

Advertisement

● LED indication and error condition
This Projector provides a function which can be specified a defective area simply by indicating the LEDs. Connect the AC
power cord, MAINS SW ON, and press the POWER ON/OFF button once and then check the LED indication.
The projector is detecting abnormal condition.
Indicators
Lamp
Ready
Warning
red
green
TEMP.
red
ERROR CONDITION
Lamp
REPLACE
orange
No power
(Primary circuit)
Temperature failure
Inside temperature is elevated
close to the abnormally high level.
Temperature failure
Inside temperature is abnormally
high. -----> Cooling
Temperature failure
Inside temperature returns to nor-
mal. -----> Standby
Lamp failure
Any of 4 lamps becomes out, Lamp
Mode is changed over from 4
lamps to 2 lamps
Lamp failure
Lamps become out
---> Cooling
Lamp failure
Lamps become out
---> Standby
Lamp Lifetime over
Power failure
(Secondary circuit)
AC cord, Fuse, Varistor,
Power board
Air Filter
Intake vents
Air Filter
Intake vents
Air Filter, Intake vents
Turning on
----> Blinking stop
Lamp,
Lamp Ballast Unit
PFC unit
Lamp,
Lamp Ballast Unit,
PFC unit
Lamp, Lamp Ballast Unit, PFC unit
Turning on
----> Blinking stop
Lamp replacement
Power failure signals,
Fan lock signals,
Lamp Cover SW, Thermal SWs
- 67 -
Troubleshooting
CHECK POINT