Sanyo PLC-XF47 Service Manual page 45

Multimedia
Hide thumbs Also See for PLC-XF47:
Table of Contents

Advertisement

13
Polarized units removal.
-5
1. Remove 6 screws-A and remove the Polarized glass units.
Red Polarized Units
2. Remove screw-B, remove the plate (A) and remove the
Prepolarized glass (IN).
3. Remove screw-C and remove the Optical filter unit.
Remove screw-E, remove the Plate (C) and remove the
Optical filter.
4. Remove 2 screws-D, remove the plates (B) and remove
the Polarized glass (IN).
Holder (A)
Polarized glass (IN)
Plate (B)
D
C
Optical filter unit
A
A
A
A
Red
Green
Blue
Prepolarized glass (IN)
D
Plate (B)
Plate (C)
E
Optical filter
Temperature sensor
(PTH901)
A
A
Blue and Green Polarized unit
2. Remove screw-B, remove the plate (A) and remove the
Prepolarized glass (IN).
3. Remove screw-C and remove the Optical filter unit.
Remove screw-F, remove the sheet and remove the
Temp. sensor (Z8P & TH).
Remove screw-E, remove the Plate (C) and remove the
Optical filter.
4. Remove 2 screws-D, remove the plates (B) and remove
the Polarized glass (IN).
B
Plate (A)
Polarized glass (IN)
Plate (B)
C
Optical filter unit
- 45 -
Optical Unit disassemblies
Holder (A)
Prepolarized glass (IN)
(Inorganic polarizer)
D
D
Plate (B)
Optical filter
Plate (C)
E
F
Temp. sensor
and Sheet
(Only Blue)
B
Plate (A)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents