Sanyo PLC-XF47 Service Manual page 32

Multimedia
Hide thumbs Also See for PLC-XF47:
Table of Contents

Advertisement

Mechanical disassemblies
6
Optical Unit removal.
1. Remove 9 screws-A, remove 4 screws-B and remove the Optical
unit.
Warning;
Do not hold the projection lens.
It may damage projection lens.
7
-1 Fan(FN906) Unit and Adjustable-feet removal.
1. Remove 6 screws-A and remove the Adjustable-foot-left.
2. Remove 6 screws-B and remove the Adjustable-foot-right.
3. Remove 2 screws-C and remove the Fan(FN906) Unit.
4. Remove 4 screws-D and remove the Fan(FN906).
5. Remove 3 screws-E and remove the Rear LED Board.
6. Remove screw-F and remove the PWB Holder.
Note;
Mark the Fans as they are removed from the holder so that
they may be reassembled in the same location from which
they were removed. Be careful of the attached direction of
Fans.
See arrow mark in a figure.
A
A
A
A
Adjustable
foot-left
Warning!
Do not hold the Projection lens
B
B
Adjustable
B
B
foot-right
B
B
A
A
A
A
A
A
B
B
C
C
Holder Fan
C
Fan (FN906) unit
- 32 -
A
A
A
A
A
This screw has been
A
removed in step 5-4.
Optical unit
B
B
D
D
D
D
F
C
E
E
E
Rear LED Board
PWB Holder

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents