Sanyo PLC-XF47 Service Manual page 35

Multimedia
Hide thumbs Also See for PLC-XF47:
Table of Contents

Advertisement

8
-3
Mains switch Unit removal.
1. Remove 4 screws-A and remove the Main-SW Unit.
2. Remove 2 screws-B and remove the Lamp Cover Switch (SW902).
3. Remove 2 screws-D and remove the AC Inlet.
4. Unhook the stoppers and remove the Mains Switch (SW901).
Push part (a) and pull the Main Switch.
5. Remove 2 screws-C and remove the Noise Filter.
To remove the Fuse.
Turns the fuse holder cover with the slot screw driver.
Remove the fuse and the fuse holder cover upward.
A A
A
A
Main SW unit
- 35 -
Mechanical disassemblies
SW902
B
Holder
B
C
C
AC Inlet
Hook
(a)
(a)
Noise Filter
SW901
LF901
Fuse holder
cover
Fuse
Fuse holder
D
D

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents