The discharge opening of the exhaust pipe must
in the direction of travel (see Fig. 12).
Rigid pipes made of unalloyed steel with a minimum wall
thickness of 1.0 mm or flexible tubes of alloyed steel are to
be used as exhaust pipes only.
NOTE:
Any collection of condensation water in the exhaust pipe
must be drained immediately; if required, it is permitted to
drill a condensation water drain hole
Fig. 11:
Exhaust muffler
Direction of flow (not specified)
preferreed direction of discharge 90°
Fig. 12:
Exhaust pipe discharge opening
Mounting position
not
point

Electrical Connections

Control Unit/Heater Connection
The electrical connection of the heaters is to be performed
in accordance with Fig. 15.
Installation and Connection of Digital Timer
Installation of the digital timer is to be performed in accordance
with Fig. 13. A drilling template is part of the scope of delivery!
Connection of the digital timer is to be performed in accord-
ance with wiring diagram Fig. 15.
Fig. 13:
Installation of Digital Timer
NOTE:
Do not press on the display panel during installation!
Vehicle Fan
±
10°
The vehicle fan is activated via the vehicle fan relay fitted
to the fuse holder, see wiring diagram Fig. 15.
NOTE:
The connection terminal in the control unit (heater) is de-
signed for one fan relay (lmax = 0,5 A).
Thermo Top
Connection of Summer/Winter Switch
NOTE:
It is not possible to connect a summer/winter switch when
a T70 is installed!
Connection of the summer/winter switch is to be performed
in accordance with Figs. 14 and 15.
NOTE:
The ends of the wires 'br' and 'vi' are inserted in the insula-
tion sleeving!
plug
timer
vi
br
Fig. 14:
Connection of Summer/Winter Switch
Installation of Telestart receiver T 70
The installation of the Telestart receiver and the aerial is to
be carried out in accordance with the T70 installation in-
structions.
'Teaching' of Telestart transmitter
Following the installation of a Tele Thermo Top heater, the
transmitter must be allocated.
The Telestart transmitter must be "taught" in accordance
with the operating instructions.