Shutting down and restarting the interface for the settings to take effect

If you change a line attribute of a T1 line, you must shut down and restart the interface for the change to
take effect.
To shut down and restart the interface, use the Serial0.0 in device config mode.
To stop the interface operation, use shutdown, and to restart it, use no shutdown.
If setting was changed after shutdown, only no shutdown is necessary.
ix1000 − 01 # enable − config
ix1000 − 01 (config) # interface Serial0.0
ix1000 − 01 (config − Serial0.0) # shutdown
ix1000 − 01 (config − Serial0.0) # no shutdown
ix1000 − 01 (config − Serial0.0) #
If setting was changed after shutdown, only no shutdown is necessary.

Saving setting data

Upon completion of setting, use the write memory command to save as startup config the data that you
have set before a restart.
ix1000 − 01 (config − Serial0.0) # exit
ix1000 − 01 (config) # write memory
ix1000 − 01 (config) #
NOTE:
Do not turn OFF the power switch while the BUSY lamp is lit. Otherwise, the data in flash mem-
ory may be destroyed.

Checking the status of interface

Check the status of interface by show interface command.
ix1000 − 01 # enable − config
ix1000 − 01 (config) # show interfaces Serial0.0
Interface Serial0.0 is up
(Omitted)
ix1000 − 01 (config) #
Enter
Enter
Enter
Enter
Enter
Enter
Enter
Enter
Check that "up" is
displayed.
– 105 –
CHAPTER 4 INITIALIZATION
SETTING UP THE WAN PRIVATE LINE (T1)
NWA-008869-001 Rev.1.0