System Specifications

TDS maximum level
<3000 ppm*
pH Range:
3-11
Pressure Ranges:
35-120 psi (2.41-8.27 bar),
40 psi (2.76 bar) minimum for nitrate reduction
Temperature Range
35˚-100˚F (2˚-38˚C)
Water Supply
0-10 grains per gallon hardness, 0 - 0.1 iron
Rated Filter Capacity
500 gallons (1895 L)
(Auxiliary and Postfilter)
Maximum Daily Production Rate
75 gpd (283 Lpd)
Membrane Discharge Water/Product
1 to 1
Water Ration:
Discharge Water/Product
3.0 to 1.0
Water Ratio:
Typical Product Water Production
40.6 gpd (153.7 Lpd)
Rate:
Efficiency Rating
24.4%
Recovery Rating
39.9%
*Note: TDS levels above 1,500mg/L must have greater than 50 psi.
The Kinetico K5 Drinking Water Station is tested and certified by NSF International against the
requirements of NSF/ANSI Standard 42 for the reduction of aesthetic chlorine, taste and odor,
Standard 53 for reduction of MTBE, and Standard 58 for the reduction of pentavalent arsenic,
barium, raduim 226/228, cadmium, VOC, copper, cysts (including oocysts of cryptosporidium
and cysts of giardia and entamoeba), fluoride, hexavalent chromium, lead, nitrate/nitrite (with test
kit Part No. 7329), selenium, TDS, trivalent chromium and turbidity.
(See performance data sheet for individual contaminants and reduction performance.)
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or
after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
The Kinetico K5 Drinking Water Station is acceptable for treatment of influent concentrations of no more than 27
mg/L nitrate and 3 mg/L nitrite in combination measured as N and are certified for nitrate/nitrite reduction only for
water supplies with a pressure of 280 kPa (40 psi) or greater.
NSF International certified our product performance, and reviewed our manufacturing facility and procedures to assure
product consistency and integrity. They also assure that our literature accurately reflects our product capabilities. The
system and installation must comply with state/provincial and local laws and regulations.
* The K5 system with the Purefecta cartridge is tested and certified by NSF International against NSF P231—
Microbiological Water Purifiers. See Purefecta data sheet for specifics. The K5 system is certified by NS F International
against NSF P231-Microbiological Water Purifiers based on the recommendations set forth in the USEPA Guide
Standard and Protocol for Microbiological Water Purifiers (OPP Task Force Report, 1987). The K5 with the Purefecta
cartridge is not intended to convert wastewater or raw sewage into drinking water.
Conforms to NSF/ANSI 58 for pentavalent arsenic reduction. See performance data sheet and Arsenic facts sheet
section for an explanation of reduction performance. The following cartridges are not NSF Certified: Arsenic Guard,
Perchlorate Guard, Chloramine Guard, and Mineral Plus.
U.S. Patent numbers 4,698,164; ,629,568; 4,650,586
Canadian Patent number 1,323,310
12
Índice
Uso de la estación de tratamiento de agua para beber Kinetico K5
Funcionamiento de la estación de tratamiento de agua para beber K5 ···· E3
Las cosas que hacen que la estación de tratamiento de agua para beber
K5 sea diferente, son las mismas que hacen que sea mejor ························· E6
Accesorios del sistema ······················································································ E8
Mantenimiento de la estación de tratamiento de agua para beber K5 ··· E9
Cambios de filtro ······················································································ E9
Apagado del sistema ············································································ E10
Equipo para nitrato/nitrito ·································································· E10
Cambios de cartuchos y desinfección ·························································· E11
Cartuchos de filtro de repuesto ···································································· E12
Especificaciones del sistema ·········································································· E13
Registro de mantenimiento ············································································ E14
Kinetico Incorporated
Kinetico Canada Incorporated
10845 Kinsman Rd.
21 Parr Blvd., Unit 10
Newbury, Ohio, 44065
Bolton, ON L7E 4G3
EE.UU.
Canadá
www.kinetico.com
www.kinetico.com
Kinetico UK Limited
Kinetico France
Bridge House
Sarl
Park Gate Business
B.P. 80528 Osny
Centre
95528 Cergy-Pontoise Cedex
Chandler's Way
Francia
Park Gate SO 31 1FQ
www.kinetico.fr
Inglaterra
www.kinetico.co.uk
····· E2
Kinetico Denmark
ApS
Sandvadsvej7
4600 Køge
Dinamarca
Kinetico Germany GmbH
Bunzlauerstrasse 12-D
Höher-Grenzhausen
Alemania 56203

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents