Waterjet - Flushing From Lop (Optional) - MTU 12 V 4000 M73 x Operating Instructions Manual

Table of Contents

Advertisement

4.15 Waterjet – Flushing from LOP (optional)
Preconditions
☑ LOCAL OPERATION illuminated pushbutton is lit brightly (local operating mode is active).
☑ Vessel is at a standstill and waterjet bucket is below the waterline.
☑ Engine speed is in engagement window.
☑ No external engagement interlock is active.
NOTICE
Waterjet flushing puts excessive strain on the bearings.
Bearing damage!
• Do not flush waterjet for too long.
• Follow instructions of the waterjet manufacturer.
Flushing with reversing gearbox and flushing mode
Item
LOP
LOP
98 | Operation | MS150045/02E 2013-07
Measure
Press FLUSH illuminated pushbutton and keep pressed (→ Page 82).
FLUSH pushbutton flashes.
Gearbox is engaged astern.
After receiving the feedback signal from coupling, the FLUSH pushbut-
ton is illuminated brightly.
Release FLUSH illuminated pushbutton.
FLUSH pushbutton flashes.
Gearbox is disengaged (neutral position).
Illumination of FLUSH pushbutton is switched off as soon as the feed-
back signal from coupling is received.

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

16 v 4000 m73 x

Table of Contents