MTU 12 V 4000 M73 x Operating Instructions Manual page 114

Table of Contents

Advertisement

141 – AL Power too high
Cause
This alarm occurs if the average
value of power over the last 24
hours exceeded the maximum
value specified in
PR1.1088.001.
142 – AL MCR exceeded 1 hour
Cause
This alarm occurs if the MCR
was exceeded for more than 1
hour within the last 12 hours.
201 – SD T-Coolant
Cause
Coolant temperature sensor
faulty; Short circuit or wire
break
202 – SD T-Fuel
Cause
Coolant temperature sensor
faulty; Short circuit or wire
break
203 – SD T-Charge Air
Cause
Charge-air temperature sensor
faulty; Short circuit or wire
break
204 – SD Level Lube Oil
Cause
lube oil level sensor faulty; Short
circuit or wire break
114 | Troubleshooting | MS150045/02E 2013-07
ZKP-Number: 11.088.007
Corrective action
u Reduce power.
ZKP-Number: 11.088.006
Corrective action
u Reduce power.
ZKP-Number: 18.004.570
Corrective action
1. Check sensor and cabling (B6), replace as necessary.
2. Error cleared after restarting the engine.
ZKP-Number: 18.004.572
Corrective action
1. Check sensor and cabling (B33), replace as necessary.
2. Error cleared after restarting the engine.
ZKP-Number: 18.004.571
Corrective action
1. Check sensor and cabling (B9), replace as necessary.
2. Error cleared after restarting the engine.
ZKP-Number: 18.004.602
Corrective action
u Check sensor and cabling, replace as necessary.

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

16 v 4000 m73 x

Table of Contents