Kenwood TK-5210 K Service Manual page 49

Vhf apco p25 transceiver
Hide thumbs Also See for TK-5210 K:
Table of Contents

Advertisement

Item
Condition
5. DQT balance 1) Adj item:[W Balance]
adjust
Adjust:[***]
•Wide
Deviation meter filter
(Concentric SW:A)
LPF:3kHz
HPF:OFF
2) Adj item:[WL Balance]t
[WLC Balance]t[WC Balance]t
[WCH Balance]t[WH Balance]
Adjust:[***]
PTT:ON
Press [B] to store the adjustment
value after adjustment.
•Narrow
3) Adj item:[N Balance]
(Concentric SW:B)
Adjust:[***]
PTT:ON
Press [B] to store the adjustment
value after adjustment.
•APCO
4) Adj item:[A Balance]
(Concentric SW:C)
Adjust:[***]
PTT:ON
Press [B] to store the adjustment
value after adjustment.
6. Max DEV
1) Adj item:[W FM Max Dev]
adjust
Adjust:[***]
•Wide
AG:1kHz/150mV at MIC terminal
(Concentric SW:A)
Deviation meter filter
LPF:15kHz
HPF:OFF
2) Adj item:[WL FM Max Dev]t
[WLC FM Max Dev]t[WC FM Max Dev]t
[WCH FM Max Dev]t[WH FM Max Dev]
Adjust:[***]
PTT:ON
Press [B] to store the adjustment
value after adjustment.
•Narrow
3) Adj item:[N FM Max Dev]
(Concentric SW:B, C)
Adjust:[***]
PTT:ON
Press [B] to store the adjustment
value after adjustment.
7. APCO high 1) Adj item:[A APCO Hi Dev]
deviation
Adjust:[***]
adjust
Deviation meter filter
LPF:3kHz
HPF:OFF
2) Adj item:[AL APCO Hi Dev]t
[ALC APCO Hi Dev]t[AC APCO Hi Dev]t
[ACH APCO Hi Dev]t[AH APCO Hi Dev]
PTT:ON
Press [B] to store the adjustment
value after adjustment.
ADJUSTMENT
Measurement
Test-
Unit
Terminal
equipment
Deviation
Panel
ANT
meter
Universal
Oscilloscope
connector
AG
AF VTVM
Adjustment
Unit
Parts
Method
Panel
[C],[D]
Make the
demodulation
waves into
square waves.
4.0kHz
(According to the
large +, -)
2.0kHz
(According to the
large +, -)
2827Hz
TK-5210
Specifications/Remarks
±50Hz
±50Hz
2771~2883Hz
49