Kenwood TK-5210 K Service Manual page 46

Vhf apco p25 transceiver
Hide thumbs Also See for TK-5210 K:
Table of Contents

Advertisement

TK-5210
• Panel tuning
SCREW
TUBE
To transceiver
• PC tuning
Connect the wires to the PCB in the connector case of
interface cable.
For output the wires out of the connector case, need to
process the connector case.
Remove the
screw
PCB layout
Shield
46
ADJUSTMENT
ADJUSTMENT
2 : RED (RX AF OUTPUT)
3 : BLACK (RX AF OUTPUT)
5 : WHITE (MIC INPUT)
6 : BROWN (MIC GND)
7 : BLUE (PTT SW) GND → ON
8 : YELLOW (PF SW)
10 : BROWN (GND)
11 : GREEN (5M)
BLU (7)
PTT SW
BRN (10)
100µ 10V
RED (2)
+
8Ω
AF Voltmeter
+
BLK (3)
100µ 10V
WHT
+
(5)
10µ 10V
Audio generator
BRN (6)
KPG-36
Connector case
100µ 10V
8Ω
+
AF voltmeter
100µ 10V
+
10µ 10V
+
Audio generator
How to Remove the Flat Cable
1. Gently draw out both sides of the connector lever uni-
formly in the direction of the arrow with tweezers.
(CN7, CN19, CN604, CN751, CN752, CN753)
CN19, CN604, CN751: K2 and K3 models only
Flat cable
2. Gently rise up the connector lever in the direction of the
arrow with a flat-head screwdriver or tweezers.
(CN603)
Note : Gently push both sides of the connector lever, when
put in the flat cable.
Flat-head
screwdriver
Lever
3. Gently depress the connector lever in the direction of the
arrow with a flat-head screwdriver or tweezers.
(CN902, CN903)
Lever
Flat cable
Tweezers
Lever
Flat cable
Flat-head
screwdriver