Shock and Vibration

These specifications apply only to the cFP-PWM-520.
NI recommends Compact FieldPoint if your application is
subject to shock and vibration.
Operating vibration, random
(IEC 60068-2-64).............................. 10–500 Hz, 5 g
Operating vibration, sinusoidal
(IEC 60068-2-6)................................ 10–500 Hz, 5 g
Operating shock
(IEC 60068-2-27).............................. 50 g, 3 ms half sine,

Hazardous Locations

U.S. (UL) .......................................... Class I, Division 2,
Canada (C-UL) ................................. Class I, Division 2,
Europe (DEMKO)............................. Ex nC IIC T4
Safety
This product is designed to meet the requirements of the following
standards of safety for electrical equipment for measurement,
control, and laboratory use:
IEC 61010-1, EN 61010-1
UL 61010-1, CSA 61010-1
Note
product label or visit
by model number or product line, and click the
appropriate link in the Certification column.
© National Instruments Corp.
For UL and other safety certifications, refer to the
18 shocks at 6 orientations;
30 g, 11 ms half sine,
18 shocks at 6 orientations
Groups A, B, C, D, T4;
Class I, Zone 2,
AEx nC IIC T4
Groups A, B, C, D, T4;
Class I, Zone 2,
Ex nC IIC T4
ni.com/certification
15
rms
, search
FP-PWM-520 and cFP-PWM-520