Guaranteed trip current
Revision E and later modules..... 12.5 A
Revision D and earlier
modules ...................................... 20 A
Trip time
Revision E and later modules..... 10 μs at 13 A
Behavior (revision E and later modules)
Current Level
0–1 A
1–9 A
9–12.5 A
12.5 A
Behavior (revision D and earlier modules)
Current Level
0–1 A
1–20 A
≥20 A

Physical Characteristics

Indicators .......................................... Green POWER and
Weight
FP-PWM-520 ............................. 140 g (4.9 oz)
cFP-PWM-520 ........................... 110 g (3.9 oz)
© National Instruments Corp.
Channel Behavior
Channel does not trip
Channel does not trip
Channel may trip
Channel trips
Channel Behavior
Channel does not trip
Channel may trip
Channel trips
13
Module Protection
Module is not damaged
Module may be damaged
Module may be damaged
Module is not damaged
Module Protection
Module is not damaged
Module may be damaged
Module is not damaged
READY indicators,
eight green output state
indicators
FP-PWM-520 and cFP-PWM-520