Specifications
VXI Requirements
Power Requirement
Physical
© National Instruments Corporation
This appendix lists the specifications for the VXI-1394 module.
VXIbus configuration space................... 64 B
A24 or A32 space................................... Programmable
Default ............................................ None
+5 V
Typical ............................................ 2.23 A
Maximum (fused) ........................... 7 A
–5.2 V
Typical ............................................ 176 mA
Maximum (fused) ........................... 1 A
–2 V
Typical ............................................ 89.5 mA
Maximum (fused) ........................... 1 A
+12 V
Typical ............................................ 750 µA
Maximum (fused) ........................... 1 A
Dimensions
Fully enclosed, shielded VXI C-size board
233.35 mm × 340 mm (9.187 in. × 13.386 in.)
Weight
VXI-1394 ........................................ 1.11 kg (2.45 lb)
(No DRAM installed)
A-1
A