S/H Characteristics
Stability
Recommended warm-up time
Offset temperature coefficient
Gain temperature coefficient

Power Requirement

+5 VDC ( 10 %)
Total power dissipation
Physical
Dimensions
I/O connectors
Input
Output
Environment
Operating temperature
Storage temperature
Relative humidity
© National Instruments Corporation
Measurement
0.012%
Track mode
7 s
acquisition
time
Hold mode
1 s
settling time
Hold step
-5 mV
Droop rate
10 mV/s
Aperture time
250 ns
Interchannel
50 ns
skew
15 min
(10 + 150/gain) V/ C
Gain
Max
(DIP-switch-
Gain Tempco
selectable)
1
25 ppm/ C
10
25 ppm/ C
100
45 ppm/ C
200
60 ppm/ C
300
80 ppm/ C
500
100 ppm/ C
600
120 ppm/ C
700
150 ppm/ C
800
200 ppm/ C
800 mA
4 W
1.8 by 7.9 by 4.9 in. (4.6 by 20.1 by 12.4 cm)
20-screw terminals
50-pin male ribbon-cable rear connector
68-pin male ribbon-cable rear connector
0 to 50 C
-55 to 150 C
5% to 90% noncondensing