Goodman APG152407041A Series Technical Manual page 41

Package gas units

Advertisement

WIRING DIAGRAMS
WARNING
L1
CC
T1
L1
LO
HI
LO
HI
L1
L1
F
P1
TH
2
HLO
1
HLI
R
3
PSW
6
W 1
PSW
W 2
8
MVL
TO
9
MICRO
MVH
Y2
7
MVC
C
5
COM
P2
Y1
1
4
5
LPS
3
6
2
ECON
LO HEAT
HI HEAT
TO
G
LO COOL
MICRO
HI COOL
DIAGNOSTIC
LED - RED
ON
OFF
1 FLASH
2 FLASHES
PRESSURE SWITCH OPEN
PRESSURE SWITCH CLOSED
3 FLASHES
4 FLASHES
5 FLASHES
6 FLASHES
COMPR. SHORT CYCLE DELAY
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
SUPPLY VOLTAG E
208-230/1/60
CC
T2
R
C
S
H
C
F
CM
L2
VM
L2
EM
L2
L2
SEE NOTE 2
TR
ALS
LS
RS
PS
M
GV
HI
C
HPS
HPS
SEE NOTE 7
SEE NOTE 8
ECON
CC
1
5
ECON
5
2
SOL
SOL
ECON
3
4
EM C
STATUS
CHECK
CHECK
NORMAL OPERATION
-
-
NO POWER OR
CHECK INPUT POWER
CHECK FUSE(S)
INTERNAL CONTROL
FAULT
GAS FLOW
GAS PRESSURE
IGNITION FAILURE
GAS VALVE
FLAME SENSOR
CHECK PRESSURE SWITCH
CHECK TUBING
CHECK VENT MOTOR
CHECK PRESSURE SWITCH
WITHOUT INDUCER ON
CHECK WIRING FOR SHORTS
CHECK MAIN LIMIT SWITCH
OPEN LIMIT SWITCH
CHECK AUXILIARY LIMIT SW.
CHECK ROLLOUT LIMIT SW.
CHECK GAS VALVE
FALSE FLAME DETECTED
CHECK FOR SHORTS IN
FLAME SENSOR WIRING
3 MIN COMP. SHORT
CYCLE DELAY
[A/G]PG15[24-60]***41**
L2
COMPONENT LEGEND
ALS
AUXILLARY LIMIT SWITCH
COMP
COMPRESSOR
L2
CM
CONDENSER MOTOR
CC
CONTACTOR
ECON
ECONOMIZER
EM
EVAPORATOR MOTOR
F
FUSE
FS
FLAME SENSOR
GND
EQUIPMENT GROUND
EQUIPMENT GROUND
GV
GAS VALVE
IIC
INTEGRATED IGNITION CONTROL
IGN
IGNITOR
LS
LIMIT SW ITCH
PS
PRESSURE SWITCH
RCCF
RUN CAPACITOR FOR COMPRESSOR/FAN
RS
ROLLOUT SWITCH
SOL
SOLENOID (2ND STAGE COOL)
TR
TRANSFORMER
VM
VENT MOTOR
NOTES
NOTES
1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF
INSULATION AS ORIGINAL.(USE COPPER CONDUCTOR ONLY).
2. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK W IRE
FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
3. USE COPPER CONDUCTORS ONLY.
4. FOR 208V OPERATION, REMOVE BLUE LEAD FROM INDUCER LOW
TERMINAL. MOVE BLACK LEAD FROM PARK TERMINAL ONTO
INDUCER LOW TERMINAL. PLACE BLUE LEAD ON PARK TERMINAL.
5. USE NEC CLASS 2 WIRE FOR THERMOSTAT FIELD WIRING.
6. COMPRESSOR 2ND STAGE SOLENOID NOT PRESENT ON ALL MODELS.
7. OPTIONAL REFRIGERANT SWITCHES
8. FOR ECONOMIZER, REMOVE PLUG FROM ECONOMIZER HARNESS.
CONNECT PLUG FROM ECONOMIZER TO HARNESS.
DIAGNOSTIC
LED - RED
LIMIT OPEN 5 TIMES IN
7 FLASHES
SAME CALL FOR HEAT
8 FLASHES
9 FLASHES
PSW/LOC OPEN
DIAGNOSTIC
LED - AMBER
OFF
NO FLAME PRESENT
ON
NORMAL FLAME PRESENT
1 FLASH
LOW FLAME SIGNAL
2 FLASHES
FALSE FLAME DETECTED
FACTORY WIRING
FACTORY WIRING
LINE VOLTAGE
LOW VOLTAGE
OPTIONAL HIGH VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
WIRE CODE
BK BLACK
BL BLUE
BR BROWN
GR GREEN
OR ORANGE
PK PINK
PU PURPLE
RD RED
WH WHITE
YL YELLOW
CHECK
STATUS
CHECK MAIN LIMIT SWITCH
CHECK AUXILIARY LIMIT SW.
CHECK JUMPER BETW EEN
1 AND 4 ON 6-CIRCUIT
IDT/ODT OPEN
CONNECTOR
CHECK OPTIONAL
REFRIGERANT SWITCHES
CHECK REFRIGERANT
SWITCHES FOR LOSS OF
CHARGE OR HIGH HEAD
PRESSURE
CHECK
STATUS
-
-
GAS FLOW
GAS PRESSURE
GAS VALVE
FLAME SENSOR
CHECK GAS VALVE
CHECK FOR SHORTS IN
FLAME SENSOR WIRING
0140G00533 REV A
41