Advertisement

3 Operation Description of Inverter

3.2.3 Abnormal status

When the inverter is abnormal, LED will display relevant abnormal code (refer to chapter 7) , press
―ST O P/RESET‖ or through multi-function digital input terminals reset inverter after abnormal is removed.

3.2.4 Parameter editing status

Press ―ENT E R‖ key and enter into status of editing parameters under stop and run status (If no user
password, need to pass user password checking status, refer to description s of password checking
status) ,during this status, we can look up or alter each parameters of inverter.

3.2.5 Password check status

Enter the status of editing parameters and 00_00 isn't equal to 0 or entering 15_XX menu (Manufacturer set
password) needs to pass user password checking status, input the right password and then press ―ENT ‖ to
enter the editing parameters status menu. If the password is wrong, the keyboard will flashing display ―Er r‖,
press ― ESC‖ returning to checking status to input password again.

3.3 Operation of operation panel

3.3.1 Inverter monitoring parameters switch

The inverter has four monitoring parameters that can circulation switch quickly(select by 00_07 ~
00_10),users can flexible select monitoring parameters they need, circulation switch between this four
monitoring parameters by press ―SHIF T ‖, shown as following figure:
3.3.2 Parameter setting operation of converter
Operation panel adopts the three levels menu design, operation is convenient:
The below grasp set an example as acceleration time 1 is 30s for 01_13, which describes the parameters
operation steps in detail:
24