10 Function Parameter
Function
Name
code
00_12
Motor control mode
00_13
Application control
00_14
Inching in operation panel
Button locked in operation
00_15
panel
00_16
Reserved
01_XX Basic function parameters
Function
Name
code
01_00
Minimum running speed
01_01
Maximum running speed
01_02
Start-up mode
01_03
Starting frequency
01_04
Starting frequency duration
01_05
DC braking time (at start)
01_06
DC braking current(at start)
01_07
Motor stop mode
01_08
DC braking speed (at stop)
01_09
DC braking waiting time(at stop)
01_10
DC braking time (at stop)
01_11
DC braking current (at stop)
01_12
Accel/decel mode
01_13
Accel time 1
01_14
Decel time 1
01_15
Accel time 2
126
Setting range and description
0: Asynchronous motor V/F control without PG
1: Asynchronous motor V/F control with PG
2: Asynchronous motor Vector control without PG
3: Asynchronous motor Vector control with PG
4: PMSM no-PG control
0: Speed control
1: Process PID control
2: Wobble frequency control
3: Customization control
4: Torque control
5: Speed / Torque control
6: Positional control (only D6A)
7: Speed /positional control (only D6A)
0: Not allow inching in operation panel
1: Allow inching in operation panel
unit: Autolocked as soon as pressing the button
0: Unlocked
1: locked except for― SHIFT‖
ten's place: ―DIR‖button to choose functions
0: Invalid
1: Effective only in the stop state
2: Valid both in running or stopped state
Setting range and description
0~01_01 rpm
01_00~15000 rpm
0: Start from starting frequency
1: DC brake first and then start from starting
frequency
2: speed tracking
0.00~60.00 Hz
0.0~10.0 s
0.0~60.0 s
0.0~150.0 % (the rated current of inverter is
100%)
0: Slowdown stop
1: Coast to stop
2: DC braking
0~3000 rpm
0.00~10.00 s
0.0~60.0 s
0.0~150.0 % (the rated current of inverter
set for100%)
0: linear accel/decel
1: S -curve accel/decel
2: autoaccel (current limit is determined by
12_02) , linear decel
0.01~600.00 s
note: Factory setting is 6.0s for models of
0.4~22 kW ,and 20.0s for30~75 kW model.
Ex-work
setting
5: PMAM PG control
Ex-work
setting
1500
0.50
0.0
0.0
0.0
0.00
0.0
50.0
Depends
on mode
Change
Addr
0
×
000CH
0
×
000DH
0
×
000EH
00
×
000FH
-
-
0010H
Change
Addr
0
×
0100H
×
0101H
0
×
0102H
0103H
0104H
0105H
0106H
0
×
0107H
50
0108H
0109H
010AH
010BH
0
×
010CH
010DH
010EH
010FH
Page
29
30
30
30
Page
56
56
35
35
35
35
35
35
35
35
35
35
37
37
37
37