10 Function Parameter

D6 series of high performance inverter divide its parameter into 00-15 group, ― the parameter number and the
group number‖ is the way to recognize. For example, ― 02_12‖ means the 12th parameter in the 2nd group.
Operation panel controls parameter by way of three menus, the number of parameter is the first one, the
number of group is the second ,and the parameter value is the last.
Some clarification about the table of the parameter:
―Fa ctory ex-work setting settings‖ means the parameter value when inverter leaved factory, or the value when
user reset the parameter to factory ex-work settings.
―Ch ange‖ means change the attribute of parameter. ―○‖means that the parameter could be changed no matter
inverter is running or stopped. ―× ‖ means it couldn't be changed when inverter is running. ― △‖means the
parameter is read-only, user couldn't change it.
Read-only parameter wouldn't be renovated when user reset the parameter to factory ex-work settings
Inverter can protect the code of parameter in order to protect user's setting. If a user sets a password (00_00
is not set to 0000), the password protection open automatically after being powered, It will enter the status of
password checking automatically before the user presses the "ENT" key to enter the status of parameter
editing, the operator must enter the correct user password to access. If the 2 minutes without any key after
password verification is passed, the password protection opens automatically while the interface display
transfers to the ex-work setting display automatically. For the factory setting parameters, manufacturers need
to enter the correct password to access.Do not try to change the parameter setted by the company, or it may
lead to abnormal working or damage.
We can enter the menu except for 15_XX
parameter) 。
CP_ XX basic parameters often used
Function
code
Digital setting of speed value
03_03
(internal speed command register 0)
03_00
Given channel of speed command
Command channel of operation
03_01
control
123
10 Function Parameter
Name
01_00~01_01 rpm
0:Digital preset of operation panel (setting
03-03)1:(set 03_03)
1:Serial communication port
3:AI1
6:Output of
7:Output of arithmetic unit 2
0: command channel of operation panel (EXT
lamp is off)
1: terminal channel (EXT lamp is on),
―ST O P/RESET‖key of keyboard is valid.
2: terminal channel (EXT lamp is on),
―ST O P/RESET‖key of keyboard is invalid.
3: serial port channel (EXT lamp blinks),
―ST O P/RESET‖key of keyboard is valid.
4: serial port channel (EXT lamp blinks),
―ST O P/RESET‖key of keyboard is invalid
through serial communication. (there is no protection for
Setting scope and description
4:AI2
5:PFI
arithmetic unit 1
Ex-work
setting
1500
2:MOP
0
0
Change Page
56
56
57