Jenn-Air JBC7624BS Design And Planning Manual page 10

Hide thumbs Also See for JBC7624BS:
Table of Contents

Advertisement

____________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________ __________________________________________________
____________________________________________________________________________________________________________________________________________________
27" DOUBLE WALL OVENS
____________________________________________________________________________________________________________________________________________________
JJW2827W, JJW2727W, JJW2527W – 26
" x 52
3
4
_______________________________________________ ____________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________________________ __
OPENING/CLEARANCE DIMENSIONS
____________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________ _____________________________________________________
A
A
F
G
H
I
D
D
Back of Cabinet
C*
C*
Conduit Channel
B
B
D
E
E
E
e
e
Bottom of Cabinet
C
F
F
FRONT VIEW
SIDE VIEW
Power Supply
Location
BACK VIEW
18
" x 26
"
1
3
4
4
MODEL #
A
Width of cabinet (min.)
B
Width of cutout
C* Height of cutout (recommended)
Top of cutout to bottom
D
of upper cabinet door (min.)
2
" (5.2 cm)
1
16
Top Cleat*
Bottom of cutout to top
E
of lower cabinet door (min.)
A
A
F
Bottom of cutout to floor
B
G
Depth of cutout (min.)
C
C
D
D
e
Recommended junction box location
*Will fit cutout height from 49
" (126.4 cm) to 51
3
4
" (1.9 cm)
" (1.9 cm)
" (1.9 cm)
3
3
3
4
4
4
ELECTRICAL REQUIREMENTS
Side Cleat*
Side Cleat*
Side Cleat*
240 volt, 40-amp fused, grounded circuit is required. A dedicated
circuit is recommended.
1
" (3.8 cm)
1
2
Platform*
The length of conduit provided is for serviceability. Do not cut the
conduit. The junction box should be located 3" (7.6 cm) maximum
below the support surface. Drill a 1
" (3.4 cm) minimum diameter
1
e
e
4
G
G
hole in the right rear corner of the support surface for access to the
junction box.
If the junction box is on the rear wall behind the oven, it must be
recessed and located in any corner of the cabinet.
e
____________________________________________________________________________________________________________________________________________________
Power Supply Location
Power Supply Location
____________________________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________ __________________________________________________
____________________________________________________________________________________________________________________________________________________
27" DOUBLE WALL OVENS – FLUSH INSTALLATION
____________________________________________________________________________________________________________________________________________________
JJW2827W, JJW2727W, JJW2527W – 26
_______________________________________________ ____________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________________________ __
OPENING/CLEARANCE DIMENSIONS
____________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________ _____________________________________________________
JJW2827W
JJW2727W
JJW2527W
in
cm
A
A
27
68.6
K
I
25
64.8
1
J
J
2
49
126.4
3
4
2
7.0
3
4
2
" (5.2 cm)
1
16
Top Cleat*
M
K
1
3.8
N
L
1
2
M
O
A
4
5
-
11.7-
N
P
8
B
B
14
37.5
3
4
24
61.0
C
D
2" (5.1 cm)
Top Cleat*
" (131.9 cm).
15
A
16
B
" (1.9 cm)
3
" (1.9 cm)
3
3
3
4
4
Side Cleat*
Side Cleat*
Side Cleat*
Side Cleat*
C
D
1
" (3.8 cm)
1
1
1
2
2
Platform*
Platform*
" (1.9 cm)
" (1.9 cm)
3
3
4
4
Side Cleat*
Side Cleat*
1
" (3.8 cm)
1
2
Platform*
E
E
e
FRONT VIEW
E
A
B
C
D
E
H
2" (5.1 cm)
e
Top Cleat*
F
A
B
C
D
" (1.9 cm)
" (1.9 cm)
3
3
4
4
D
Side Cleat*
Side Cleat*
E
1
" (3.8 cm)
1
2
Platform*
E
G
TOP VIEW
* Cleats and platform must be recessed 1" (2.5 cm) from the front of the cabinet.
Power Supply Location
" x 52
" x 24
" (depth without handles)
3
1
3
4
4
4
F
G
H
I
2
" (7.0 cm)
2
" (7.0 cm)
3
3
4
4
Top Cleat*
Top Cleat*
Conduit Channel
A
B
C
D
" (1.9 cm)
" (1.9 cm)
" (1.9 cm)
3
4
4
A
4
Side Cleat*
B
" (3.8 cm)
1
" (3.8 cm)
1
2
Platform*
F
F
e
e
C
E
E
F
SIDE VIEW
Power Supply
Location
F
Side Cleat*
Side Cleat*
1" (2.5 cm)
BACK VIEW
JJW2827W
JJW2727W
MODEL #
JJW2527W
in
cm
A
Width of flush inset cutout (min.)
27
68.6
B
Width of opening (min.)
25
64.8
1
2
C
Height of flush inset cutout (min.)
54
137.2
D
Height of opening (min.)
49
3
126.4
4
Back of Cabinet
4
-
11.7-
5
8
E
Bottom of cutout to floor
14
37.5
3
4
F
Depth of cutout (min.)
25
63.5
e
Recommended junction box location
D
ELECTRICAL REQUIREMENTS
E
240 volt, 40-amp fused, grounded circuit is required. A dedicated
circuit is recommended.
The length of conduit provided is for serviceability. Do not cut the
conduit. The junction box should be located 3" (7.6 cm) maximum
below the support surface. Drill a 1
" (3.4 cm) minimum diameter
1
4
hole in the right rear corner of the support surface for access to the
junction box.
If the junction box is on the rear wall behind the oven, it must be
recessed and located in any corner of the cabinet.
FLUSH INSTALLATION REQUIREMENTS
Bottom of Cabinet
A 25" (63.5 cm) minimum cutout depth is required.
These dimensions will result in a
3
" (1.0 cm) reveal on the top,
8
a
1
" (0.3 cm) reveal on the sides and a 1
3
" (3.5 cm) reveal on the
8
8
bottom of the wall oven.
The front face of the cleats and platform will be visible and should
be treated as a finished surface.
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents