GENERAL INFORMATION

EARLY SIGNS OF CARBON MONOXIDE POISONING RESEMBLE THE FLU, WITH HEADACHE, DIZZINESS
AND/OR NAUSEA. IF YOU HAVE THESE SIGNS, THE APPLIANCE MAY NOT BE WORKING PROPERLY.
SOME PEOPLE--PREGNANT WOMEN, PERSONS WITH HEART OR LUNG DISEASE, ANEMIA, THOSE
UNDER THE INFLUENCE OF ALCOHOL, THOSE AT HIGH ALTITUDES--ARE MORE AFFECTED BY
THIS APPLIANCE MUST NOT BE INSTALLED IN A BEDROOM OR BATHROOM.
THE APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE.
THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES.
For your satisfaction, this appliance has been test-fi red to assure its operation and quality!
Altitude (FT)
Max input (BTU/HR)
Min Inlet Gas Supply Pressure
Max Inlet Gas Supply Pressure
Manifold Pressure (Under Flow
Conditions)
This appliance is for installation in a solid fuel burning fi replace or listed ventless fi rebox enclosures only.
No external electricity (110 volts or 24 volts) is required for
the gas system operation.
This appliance is equipped with a pilot light safety system
referred to as an oxygen depletion sensor (ODS) and is
designed to turn off the appliance if not enough fresh air is
available.
Napoleon's two vent free fi rebox enclosures the ZCVF
36/42 can be used to house all 3 of Napoleon's vent free
log sets, the GVFL 18, 24 and 30.
2.4

MINIMUM APPLIANCE SIZE

LOG SET
HEIGHT
GVFL18
GVFL24
GVFL30
W415-0809 / B / 01.07.11
CARBON MONOXIDE POISONING MAY LEAD TO DEATH
GET FRESH AIR AT ONCE! HAVE APPLIANCE SERVICED.
CARBON MONOXIDE THAN OTHERS.
0-4,500
40,000
4.5" Water
Column
7" Water
Column
3.5" Water
Column
WIDTH
DEPTH
18"
24"
18"
28"
18"
34"
WARNING
!
GVFL18
NG
LP
NG
0-4,500
0-4,500
40,000
40,000
11" Water
4.5" Water
Column
Column
13" Water
7" Water
Column
Column
10" Water
3.5" Water
Column
Column
www.nficertified.org
Each gas log set must be installed into a appliance cavity
with a minimum size.
14"
14"
Refer to the table to determine the appropriate minimum
appliance size.
14"
GVFL24
GVFL30
LP
NG
0-4,500
0-4,500
40,000
40,000
11" Water
4.5" Water
Column
Column
13" Water
7" Water
Column
Column
10" Water
3.5" Water
Column
Column
We suggest that our gas
hearth products be installed
and serviced by profes-
sionals who are certified in
the U.S. by the National
Fireplace Institute
NFI Gas Specialists.
LP
0-4,500
40,000
11" Water
Column
13" Water
Column
10" Water
Column
(NFI) as
®