Napoleon Torch GVFT8N Installation And Operating Instructions Manual

Vent free natural gas propane

Advertisement

Quick Links

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
CERTIFIED UNDER AMERICAN NATIONAL STANDARDS, ANSI Z21.11.2B, VOLUME II FOR UNVENTED ROOM HEATERS.
VENT FREE
GVFT8N
NATURAL GAS
GVFT8P
PROPANE
CERTIFIED FOR THE UNITED STATES USING ANSI METHODS.

SAFETY INFORMATION

WARNING
!
If the information in these instructions are
not followed exactly, a fi re or explosion
may result causing property damage,
personal injury or loss of life.
- Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fi re department.
- Installation and service must be performed by a
qualifi ed installer, service agency or the supplier.
- This is an unvented gas-fi red heater that
uses air (oxygen) from the room in which it is
installed. Provisions for adequate combustion and
ventilation air must be provided.
Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleon.on.ca
$10.00
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
INSTALLATION AND
1.3
W415-0847 / 09.15.09
1

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon Torch GVFT8N

  • Page 1: Safety Information

    Provisions for adequate combustion and ventilation air must be provided. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleon.on.ca $10.00...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INSTALLATION OVERVIEW INTRODUCTION DIMENSIONS GENERAL INSTRUCTIONS GENERAL INFORMATION RATING PLACE LOCATION CARE OF GLASS INSTALLATION COMBUSTION AND VENTILATION AIR PROVISIONS DETERMINING CONFINED OR UNCONFINED SPACE GAS INSTALLATION GAS PRESSURE ELECTRICAL CONNECTION CLEARANCE TO COMBUSTIBLES MOUNTING CABINET INSTALLATION FINISHING DOOR REMOVAL GLASS REMOVAL...
  • Page 3: Installation Overview

    1.0 INSTALLATION OVERVIEW Mounting cabinet, see “MOUNT- ING CABINET INSTALLATION” section. Glass, see “GLASS REMOVAL” section. Door, see “DOOR REMOVAL” section. Frame, see “FRAME INSTALLATION” section. Logo, see “LOGO PLACEMENT” section. W415-0847 / 09.15.09...
  • Page 4: Introduction

    2.0 INTRODUCTION WARNING • THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED. • ANY CHANGES TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND IS PROHIBITED. WARNING • Under no circumstances should this appliance be modifi ed. •...
  • Page 5: Dimensions

    DIMENSIONS RATING PLATE LOCATION ELECTRICAL GAS LINE ACCESS ACCESS GENERAL INSTRUCTIONS WARNING CARBON MONOXIDE POISONING MAY LEAD TO DEATH EARLY SIGNS OF CARBON MONOXIDE POISONING RESEMBLE THE FLU, WITH HEADACHE, DIZZI- NESS AND/OR NAUSEA. IF YOU HAVE THESE SIGNS, THE HEATER MAY NOT BE WORKING PROP- ERLY.
  • Page 6 USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH THIS APPLIANCE. USING NON-LISTED ACCESSORIES AND REPLACEMENT PARTS (BLOWERS, LOUVRES, TRIMS, GAS COMPONENTS, VENT COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE LIMITED LIFETIME WARRANTY. This gas appliance should be installed and serviced by a qualifi ed installer to conform with local codes.
  • Page 7: General Information

    GENERAL INFORMATION FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND QUALITY! RATES AND EFFICIENCIES NATURAL GAS PROPANE Altitude 0 - 2,000* 0 - 2,000* Maximum input 6,000 6,000 Minimum Inlet Gas Supply Pressure 4.5” Water Column 11”...
  • Page 8: Installation

    3.0 INSTALLATION COMBUSTION AND VENTILATION AIR PROVISIONS This appliance shall not be installed in a confi ned space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. The National Fuel Gas Code, ANSI Z223.1 defi nes a confi ned space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfi ned space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space.
  • Page 9 Without suffi cient fresh air for proper operation, poor fuel combustion can result. Carbon Monoxide is a result of poor combustion. If additional fresh air is required, use one of the methods described in the National Fuel Gas Code, ANSI Z223.1, Section 5.3 or the applicable local code.
  • Page 10: Gas Installation

    GAS INSTALLATION WARNING RISK OF FIRE, EXPLOSION OR ASPHYXIATION. ENSURE THERE ARE NO IGNITION SOURCES SUCH AS SPARKS OR OPEN FLAMES. SUPPORT GAS CONTROL WHEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING GAS LINE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 11: Gas Pressure

    GAS PRESSURE Outlet pressure can be checked to ensure it is measuring 3.5” W.C. (NG) or 10.0” W.C. (LP). NPT BARB FITTING 3.4.1 Outlet pressure can be checked by removing cap (A) using a 3/16 Allen key and replacing it with a 1/8 NPT barb fitting. 3.4.2 Place pressure gauge tube over the fitting.
  • Page 12 ELECTRICAL BOX COVER (C/W 2 RECEPTACLES) CABLE CONNECTOR GROUND SCREW GROUND WIRE NUTS ELECTRICAL BOX (C/W GROUND SCREW) W415-0847 / 09.15.09...
  • Page 13: Clearance To Combustibles

    CLEARANCE TO COMBUSTIBLES WARNING THIS APPLIANCE MUST BE INSTALLED IN THE CABINET PROVIDED. THE CABINET IS DESIGNED TO BE INSTALLED ON FINISHED SURFACES. WARNING THIS APPLIANCE CAN BE RECESSED INTO AN ALCOVE A MAXIMUM OF 12” PROVIDED THAT ALL CLEARANCES ARE MAINTAINED. THE CABINET MAY BE INSTALLED DIRECTLY ONTO A COMBUSTIBLE SURFACE.
  • Page 14: Mounting Cabinet Installation

    MOUNTING CABINET INSTALLATION WARNING DEFLECTOR MUST BE INSTALLED. 3.7.1 Using the installation template (W122-0401) sup- WARNING INSTALLATION plied, determine the best mounting location for TEMPLATE your new Torch, see “DIMENSIONS” or “MINIMUM CLEARANCE TO COMBUSTIBLES” section. Mark DEFLECTOR all 14 hole centres on the wall (surface) using the template.
  • Page 15: Finishing

    4.0 FINISHING DOOR REMOVAL WARNING BEFORE DOOR IS REMOVED TURN THE APPLIANCE OFF AND WAIT UNTIL APPLIANCE IS COOL TO THE TOUCH. DOORS ARE HEAVY AND FRAGILE SO HANDLE WITH CARE. WARNING The door is held in place at the bottom by a retainer tab that inserts into a slot in the bottom edge of the door, and at the top with a tab that secures in the same fashion.
  • Page 16: Frame Installation

    FRAME INSTALLATION 4.3.1 Align the two holes in the upper portion of the hinge BOTTOM on the control door to those BOTTOM TRIM W385 -0479 in the bottom trim bracket, TRIM BRACKET secure using two of the #8 W385- 0479 BRACKET W385 -0479 x 1/2”...
  • Page 17: Logo Placement

    RECEIVING SLOTS LOGO PLACEMENT With the control door closed, affix the logo to the front face of the control door at the bottom left corner. SLOT CONTROL DOOR 1/4” (APPROX.) TRIM BRACKET 1/4” (APPROX.) GLASS MEDIA INSTALLATION FRAME WARNING (REAR VIEW) CLEAN THE GLASS EMBERS PRIOR TO INSTALLATION.
  • Page 18: Lk8 Light Installation (Optional)

    LK8 LIGHT INSTALLATION (OPTIONAL) 4.6.1 Turn off the electrical and gas supply to the appliance. 4.6.2 Remove the frame from the appliance by removing the 2 stain- less steel hex head securing screws from the bottom and lifting the frame off of the top trim bracket. 4.6.3 Lay the frame down on its front, being careful not to scratch the fin- ish.
  • Page 19: Operation

    5.0 OPERATION WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. If appliance shuts off, do not relight until you provide fresh air. If appliance keeps shutting off, have it serviced.
  • Page 20: Adjustments

    6.0 ADJUSTMENTS VENTURI ADJUSTMENT This model has an air shutter that has been factory set open according to the chart below: Closing the air shutter will cause a more yellow fl ame, but can lead to carboning. Opening the air shutter will cause a more blue fl ame, but can cause fl ame lifting VENTURI from the burner ports.
  • Page 21: Maintenance

    7.0 MAINTENANCE TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. This appliance should be inspected before use and at least annually by a qualified service person.
  • Page 22: Replacements

    REGULATOR - LP W455-0085 #56 NATURAL GAS ORIFICE W455-0086 #69 PROPANE GAS ORIFICE W475-0590 BACK PANEL W300-0108 ACCESS GLASS (BLACK) W385-0334 NAPOLEON LOGO W562-0046 ROPE GASKET, BACK PANEL W385-0479 CONTROL PANEL LABEL W200-0300 CONTROL PANEL W660-0088 ROCKER SWITCH - ON/OFF W660-0082 ROCKER SWITCH - LIGHTS Items not shown to scale.
  • Page 23 ACCESSORIES PART NO. DESCRIPTION TMCSS MOUNTING CABINET TFSSO FRAME KIT LIGHT KIT W415-0847 / 09.15.09...
  • Page 24: Trouble Shooting

    9.0 TROUBLE SHOOTING WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT, WITH THE GLASS DOOR OPEN OR REMOVED. SYMPTOM PROBLEM TEST SOLUTION Flame length Unit is over-fi red or under- Check pressure readings.
  • Page 25: Warranty

    NAPOLEON® warrants its stainless steel burners against defects in workmanship and material for life, subject to the following conditions: During the fi rst 10 years NAPOLEON® will replace or repair the defective parts at our option free of charge. From 10 years to life, NAPOLEON®...
  • Page 26: Service History

    11.0 SERVICE HISTORY 43.1 W415-0847 / 09.15.09...
  • Page 27: Notes

    12.0 NOTES 44.1 W415-0847 / 09.15.09...
  • Page 28 44.1 W415-0847 / 09.15.09...

This manual is also suitable for:

Torch gvft8p

Table of Contents