  • Page 1 W415-0559 / 02.07.06 W415-0559 / 02.15.06...
  • Page 2: What To Do If You Smell Gas

    WARNINGS & SAFETY PRECAUTIONS Do not store gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch. W415-0559 / 02.15.06 Installation and service must be performed by a qualified installer,...
  • Page 3 TABLE of CONTENTS Warnings and Safety Precautions What to do if you smell gas Warranty General Instructions General Information Mobile Home Installation Location and Clearances Pilot Indicator Light - Battery Install Blower Installation Gas Installation Finishing Screen Installation and Removal Cast Front Installation and removal Log Placement Logo Placement...
  • Page 4 NAPOLEON products are manufactured under the strict Standard of the world recognized NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fi red at a quality test station. The complete fi replace is test-fi...
  • Page 5 GENERAL INSTRUCTIONS ANY CHANGE TO THIS HEATER OR ITS CON- TROLS CAN BE DANGEROUS AND IS PROHIB- ITED. THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. Installation practices vary from region to region and it is important to know the specifi...
  • Page 6: Location And Clearances

    CARBON MONOXIDE POISONING MAY LEAD TO DEATH Early signs of carbon monoxide poisoning resemble the fl u, with headache, dizziness and/ or nausea. If you have these signs, the heater may not be working properly. LOCATION & CLEARANCES THIS GAS STOVE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. Installation practices vary from region to region and it is important to know the specifi...
  • Page 7: Blower Installation

    BLOWER INSTALLATION Blower ( SEE LOCATION AND CLEARANCES IN INSTRUCTION MANUAL 1. Cut and remove the tie securing the blower switch wires to the heat shield. 2. Connect the white wire coming from below the unit to the terminal on the blower. 3.
  • Page 8 CAST FRONT INSTALLATION AND REMOVAL 1. Lift the top cast piece off of the unit. 2. Detach the front cast piece from the side pieces by remov- ing the screws from the brackets located in the upper inside corners. 3. Slide the front straight up to remove. SCREWS FRONT Follow the above steps in reverse in order to reinstall...
  • Page 9 LOG PLACEMENT In order to assemble the log set, the screen and cast front must be removed, see Cast Front / Screen Removal in the Finishing section of this manual. 1. Place the rear log, as shown, onto the rear log support brackets.
  • Page 10: Operation

    OPERATING INSTRUCTIONS If heater shuts off, do not relight until you pro- vide fresh air. If heater keeps shutting off, have it serviced. Keep burner and control compartment clean. WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
  • Page 11 TURN OFF THE GAS AND UNPLUG ELEC- TRICAL POWER BEFORE SERVICING THE STOVE! CAUTION: Label all wires prior to disconnection when servic- ing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. This stove should be inspected before use and at least annually by a qualifi...
  • Page 12 Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor. When ordering replacement parts always give the following information: FOR WARRANTY REPLACEMENT PARTS OF THE ORIGINAL INVOICE WILL BE REQUIRED TO HON OUR THE CLAIM REPLACEMENT PARTS PART #...
  • Page 13 * WARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd. W415-0559 / 02.15.06...
  • Page 14: Troubleshooting Guide

    TROUBLE SHOOTING GUIDE SYMPTOM PROBLEM Main burner goes Pilot fl ame is not large enough out; pilot stays on. or not engulfi ng the thermo- pile Thermopile shorting Remote wall switch wire is too long; too much resistance in the system. Faulty thermostat or switch.
  • Page 15 SYMPTOM PROBLEM Pilot goes out while Gas piping is undersized. s t a n d i n g ; M a i n burner is in ‘OFF’ position. Flames are consis- Unit is over-fi red or under- tently too large or fi...
  • Page 16 NOTES Fireplace Service History This fireplace must be serviced annually depending on usage DATE SERVICE TECHNICIAN NAME SPECIAL CONCERNS DEALER NAME SERVICE PERFORMANCE W415-0559 / 02.15.06...