Napoleon Fiberglow Series Installation And Operation Manual

Napoleon Fiberglow Series Installation And Operation Manual

Hide thumbs Also See for Fiberglow Series:

Advertisement

NATURAL GAS MODELS:
PROPANE GAS MODELS:
SAFETY INFORMATION
WARNING
!
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
- Do not store or use gasoline or other
fl ammable vapors and liquids in the vicinity of
this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call
the fi re department.
- Installation and service must be
performed by a qualifi ed installer, service
agency, or the supplier.
- This is an unvented gas-fi red heater that
uses air (oxygen) from the room in which
it is installed. Provisions for adequate
combustion and ventilation air must be
provided. Refer to section "combustion
and ventilation air provisions".
This appliance may be installed in an aftermar-
ket, permanently located, manufactured-home
(USA only) or mobile home, where not
prohibited by local codes.
This appliance is only for use with the type of
gas indicated on the rating plate. This appliance
is not convertible for use with other gases.
INSTALLER:
Leave this manual with the appliance
CONSUMER:
Retain this manual for future reference
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030
$10.00
GVFL18N / GVFL24N / GVFL30N
ADD PRODUCT CODE HERE (TRADE GOTHIC LT STD FONT)
GVFL18P / GVFL24P / GVFL30P
CERTIFICATION
Phone 1 (866) 820-8686 • www.napoleon.com • hearth@napoleon.com
INSTALLATION AND
ADD MANUAL TITLE
OPERATION MANUAL
Insert appropriate statement (see margins).
ANSI Z21.60 / CSA 2.26 DECORATIVE GAS APPLIANCES FOR INSTALLATION IN SOLID-FUEL
ANSI _______ FOR _____________________________________________________
These log sets can be installed in vented or unvented applications.
LOGO
BARCODE LABEL ON THE OWNER'S MANUAL"
Fiberglow™ Series
Product Name / Code
(MUST use title from Price Book)
ADD ____ ILLUSTRATED
ADD PRODUCT IMAGE
FOR INDOOR USE ONLY
CERTIFIED TO THE AMERICAN NATIONAL STANDARD:
CERTIFIED TO: ANSI Z21.11.2 UNVENTED HEATERS
IF INSTALLATION + OPERATION, ADD SERIAL
NUMBER LABEL HERE
IF SEPARATE MANUALS, ADD "PLACE
ENGLISH
GVFL18
GVFL24
GVFL30
BURNING APPLIANCES
W415-0809 / D / 02.26.21

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon Fiberglow Series

  • Page 1 CERTIFICATION LOGO BARCODE LABEL ON THE OWNER’S MANUAL” Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone 1 (866) 820-8686 • www.napoleon.com • hearth@napoleon.com $10.00 W415-0809 / D / 02.26.21...
  • Page 2 safety information WARNING DANGER • This appliance is hot when operated and can cause severe burns if contacted. • Any changes or alterations to this appliance or its controls can be dangerous and is prohibited. HOT GLASS WILL CAUSE • Do not operate appliance before reading and BURNS.
  • Page 3 • Do not allow wind or fans to blow directly into the appliance. Avoid any drafts that alter burner fl ame patterns. RAAK HET GLAS NIET AAN TOT HET IS AFGEKOELD. DUTCH safety information LAAT KINDEREN NOOIT HET GLAS AANRAKEN. WARNING Dit apparaat is voorzien van een barrière die is ontworpen om het risico van brandwonden door het hete kijkglas te beperken.
  • Page 4: Table Of Contents

    table of contents general information minimum appliance size general instructions rating plate information dimensions installation installation in an unvented application 3.1.1 combustion and ventilation air provisions 3.1.2 determining confined or unconfined space installing in a vented application 3.2.1 damper stop installation gas piping finishing andiron and grate assembly...
  • Page 5: General Information

    Specialists Napoleon’s two vent free firebox enclosures the ZCVF www.n certi ed.org 36/42 can be used to house all 3 of Napoleon’s vent free log sets, the GVFL 18, 24 and 30. This appliance is intended for supplemental heating. minimum appliance size...
  • Page 6: General Instructions

    general information general instructions WARNING • Always light the pilot whether for the first time or if the gas supply has ran out, with the glass door opened or removed. • Provide adequate clearance for servicing and operating the appliance. •...
  • Page 7: Rating Plate Information

    WIDTH DEPTH MANUAL. Refer to the Intertek Directory of Building Products (https://bpdirectory.intertek.com) for detailed information WOLF STEEL LTD. GVFL18 18” 24” 14” 24 NAPOLEON ROAD. BARRIE, ONTARIO L4M 0G8 CANADA GVFL24 18” 28” 14” SERIAL NUMBER: GVFL GVFL30 18” 34”...
  • Page 8: Dimensions

    dimensions 2.0 dimensions GVFL18 13 1/4" 336mm 20 1/2" 521mm 24" 610mm GVFL18 ILLUSTRATED GVFL24 24" 610mm 13 1/4" 336mm 26 1/4" 667mm GVFL24 ILLUSTRATED GVFL30 24" 610mm 22 3/4" 578mm 1 1/2" 38mm 13 1/4" 336mm 30 1/4" 768mm GVFL30 ILLUSTRATED W415-0809 / D / 02.26.21...
  • Page 9: Installation

    installation 3.0 installation installation in an unvented application WARNING • Barriers such as the bottom of a glass door frame placed in front of a gas log set can change the air flow characteristics of the appliance which in turn can cause the appliance to carbon or overheat and malfunction. During manufacturing, fabricating and shipping various components of this appliance are treated with certain oils, films or bonding agents.
  • Page 10: Installing In A Vented Application

    B) Weather stripping has been added on openable windows and doors other openings. C) Caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and An unvented room appliance is recommended for use as a secondary heat source rather than as a primary source. Gas fl oors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at combustion produces water vapour which could occur at the rate of approximately one ounce of water for every 1,000 installation...
  • Page 11: Gas Piping

    installation Use the 3” adjustable bolt to adjust the damper to the MINIMUM DAMPER OPENING correct opening, based on the enclosed chart. (SQUARE INCHES) Should the damper stop not fit, or provide the required CHIMNEY MASONRY FACTORY BUILT permanent opening from the Minimum Damper HEIGHT APPLIANCE APPLIANCE...
  • Page 12: Finishing

    finishing 4.0 finishing andiron and grate assembly USE ONLY ACCESSORIES With the 2 andirons laying face down, DESIGNED FOR AND secure the grate overtop using 2x LISTED WITH YOUR ¼-20 bolts (supplied in the manual SPECIFIC LOG SET. baggie). Install the grate/andiron assembly to the burner base using 4x ¾”...
  • Page 13: Log Placement

    Do not place glowing embers, charcoal embers, vermiculite or charcoal lumps on this burner. Phazer logs, exclusive to Napoleon, provide a unique and realistic glowing effect that is different in every installa- tion. These logs are fuel specific. Do not interchange. Refer to the replacement parts list.
  • Page 14: Logo Placement

    finishing logo placement Remove the backing of the logo supplied. Centre the logo on the front of the appliance, ½” in from the left side, as shown. ½" ½" ½" media WARNING • All previously applied loose material must be removed prior to reapplication Place lava or ember rock around the base of the appliance, making sure not to block any burner ports or valve access.
  • Page 15: Operating Instructions

    operating instructions 5.0 operating instructions If the appliance is equipped with decorative glass doors, they must be fully opened when operating this gas log set. lighting instructions Locate the pilot burner at the rear of the log set on the right side.
  • Page 16: Operation

    operation 6.0 operation WARNING • If you do not follow these instructions exactly, a fi re or explosion may result causing property damage, personal injury, or loss of life. • If applicable, always light the pilot whether for the fi rst time or if the gas supply has run out with the glass door opened or removed.
  • Page 17: Adjustments

    Flame must envelop upper 3/8" to 1/2" 7.0 adjustments adjustments (12.7mm - 9.5mm) of Flame sensor air shutter WARNING DEXEN EI • Carbon can be distributed in surrounding living areas if the air shutter is improperly adjusted. • Failure to keep the primary air opening(s) of the burneer(s) clean may result in sooting and property damage. The air shutter settings are factory set for most installations.
  • Page 18: Maintenance

    maintenance 8.0 maintenance WARNING • Turn off the gas and electrical power before servicing the appliance. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. Visually inspect the appliance for carbon buildup. Using a small whisk or brush, brush off the excess carbon and vacuum up or sweep into the garbage. Check the appliance for broken logs and corrosion of the main burner base.
  • Page 19: Replacement Parts

    9.0 replacement parts replacement parts WARNING • Failure to position the parts in accordance with this manual or failure to use only parts specifi cally approved with this appliance may result in property damage or personal injury. Contact your dealer for questions concerning prices and policies on replacement parts. Normally, all parts can be ordered through your Authorized dealer / distributor.
  • Page 20 #50 ORIFICE - LP W660-0023 ON / OFF SWITCH W725-0030 VALVE - NG W725-0031 VALVE - LP W385-0334 NAPOLEON LOGO W662-0003 NATURAL GAS - OXYGEN DEPLETION SENSOR W662-0004 PROPANE GAS - OXYGEN DEPLETION SENSOR W135-0394 FIBRE BURNER COVER W010-2120 WELDED BURNER ASSEMBLY...
  • Page 21: Accessories

    10.0 accessories accessories ACCESSORIES REF NO. PART NO. DESCRIPTION GD-660 REMOTE WALL SWITCH W/20” WIRE W660-0026 PROGRAMMABLE TIMER W550-0006 ADDITIONAL LAVA ROCK / CINDERS W415-0809 / D / 02.26.21...
  • Page 22: Troubleshooting

    11.0 troubleshooting troubleshooting WARNING • Always light the pilot whether for the fi rst time or if the gas supply has run out with the glass door open or removed. • Turn off the appliance completely and let cool before servicing. Only a qualifi ed service person should service and repair this electric appliance.
  • Page 23 troubleshooting symptom problem test solution Pilot will not light. Out of propane gas. Fill the tank. INSERT No spark at pilot burner. Check if pilot can be lit by a match. Check that the wire is connected to the push button ignitor. PHOTO Check if the push button ignitor needs tightening.
  • Page 24: Warranty

    Napoleon neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product. Napoleon will not be responsible for: over- fi ring, downdrafts, spillage caused by environmental conditions such as rooftops, buildings, nearby trees, hills, mountains, inadequate vents or ventilation, excessive venting confi gurations, insuffi cient makeup air, or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.
  • Page 25: Service History

    13.0 service history service history W415-0809 / D / 02.26.21...
  • Page 26 notes 29.1 W415-0809 / D / 02.26.21...
  • Page 27 notes 29.1 W415-0809 / D / 02.26.21...
  • Page 28 NAPOLEON CELEBRATING OVER 40 YEARS OF HOME COMFORT PRODUCTS 7200, Route Transcanadienne, Montréal, Québec H4T 1A3 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 103 Miller Drive, Crittenden, Kentucky, USA 41030 De Riemsdijk 22, 4004 LC Tiel, The Netherlands Phone: 1-866-820-8686 napoleon.com...

This manual is also suitable for:

Gvfl18nGvfl18pGvfl24nGvfl24pGvfl30pGvfl30n

Table of Contents