Euroheat Nestor Martin IN13 Installation & Servicing Instructions Manual

Hide thumbs Also See for Nestor Martin IN13:

Advertisement

Quick Links

This Manual Must Always be Available to the Stove Operator
Smoke
Control
Exempt
This manual must be used in
conjunction with document IN1173.
The Wood and Mutlifuel Chimney
and Installation Guide.
Euroheat
Natural Energy Company
Installation

Servicing Instructions

Nestor Martin
IN13
IN1208 Edition B June 2010
PART NUMBER
SERIAL NUMBER
&

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Nestor Martin IN13 and is the answer not in the manual?

Questions and answers

Summary of Contents for Euroheat Nestor Martin IN13

  • Page 1: Servicing Instructions

    This Manual Must Always be Available to the Stove Operator Euroheat Natural Energy Company Installation & Servicing Instructions Nestor Martin IN13 Smoke Control IN1208 Edition B June 2010 Exempt PART NUMBER SERIAL NUMBER This manual must be used in conjunction with document IN1173.
  • Page 2: Table Of Contents

    Local Authority Building Control Department. For more details contact HETAS. (Contact details page 3) Euroheat would suggest only Registered Competent Engineers such as HETAS approved engineers install Euroheat appliances. If a competent engineer is not employed to install your appliance, building control must to contacted and a building control number is issued.
  • Page 3: The Model Range Explained

    Please ensure the warranty registration form is completed if you are the installer and confirm with the user that it is their responsibility to return it to Euroheat. In this way the model and its history will be recorded for reference in the future.
  • Page 4 Your attention is drawn to the precautions and responsibilities under the Health and Safety at Work Acts,  and whatever new legislation being introduced during the life of this document. © EUROHEAT DISTRIBUTORS (H.B.S) LTD. June 2010 E & OE Instructions Part number IN1208 Edition B...
  • Page 5: Technical Data, Intermittent Operation

    0mm²** ** In well sealed properties additional free air might be required. IN13 Aperture Size 550mm Min/ 580mm Max 370mm Min 406mm Min/470mm Max © EUROHEAT DISTRIBUTORS (H.B.S) LTD. June 2010 E & OE Instructions Part number IN1208 Edition B...
  • Page 6 Approx 1.4m Self-adhesive Rope Which may be used to form a seal between the stove and the fireplace aperture. 1 x Heat Resistant Leather Glove © EUROHEAT DISTRIBUTORS (H.B.S) LTD. June 2010 E & OE Instructions Part number IN1208 Edition B...
  • Page 7 5. Ensure that clearances to any combustible materials surrounding the aperture conform to those on page 11. © EUROHEAT DISTRIBUTORS (H.B.S) LTD. June 2010 E & OE Instructions Part number IN1208 Edition B...
  • Page 8: Housing Construction, Without An Existing Chimney Breast

    Whilst this may sound daunting the reward will be a vast increase in heating efficiency. © EUROHEAT DISTRIBUTORS (H.B.S) LTD. June 2010 E & OE...
  • Page 9: Ideal Installation

    Structural lintel Insulation may be fitted around the stove body if there is enough room within the fireplace opening Level and stable supporting hearth © EUROHEAT DISTRIBUTORS (H.B.S) LTD. June 2010 E & OE Instructions Part number IN1208 Edition B...
  • Page 10: The Flue

    300mm of solid stainless steel flue pipe must fitted prior to the flexible flue liner. Bends can be utilized to achieve the correct position. © EUROHEAT DISTRIBUTORS (H.B.S) LTD. June 2010 E & OE...
  • Page 11: The Hearth And Fire Surround

    300mm. A fire guard must be fitted if children or infirm adults are at risk of coming into contact with the stove. © EUROHEAT DISTRIBUTORS (H.B.S) LTD. June 2010 E & OE Instructions Part number IN1208 Edition B...
  • Page 12: Minimum Air Setting

    The facia plate will have to be removed to access the adjustment screw. Any adjustment should be only undertaken by the commissioning engineer or under direction from the Euroheat Technical Department. Minimum Air Adjustment Screw Turn the adjustment screw clockwise to increase and anti-clockwise to decrease the minimum air setting.
  • Page 13: Firebox Components

    It can then be angled within the fire box to withdraw it through the door. To refit the replacement reverse the procedure. © EUROHEAT DISTRIBUTORS (H.B.S) LTD. June 2010 E & OE Instructions Part number IN1208 Edition B...
  • Page 14 It is secured to the top of the stove by two stainless steel bolts. It MUST be replaced after sweeping. Failure to fit this baffle will cause reduced performance and may eventually damage the stove. © EUROHEAT DISTRIBUTORS (H.B.S) LTD. June 2010 E & OE Instructions Part number IN1208 Edition B...
  • Page 15 For the latest editions of all Euroheat documentation visit our web site www.euroheat.co.uk. We would request that you inform Euroheat of information which you feel is not provided in this document which would assist other users in the future.
  • Page 16 10,000 pages of technical information, spare parts, product shots, news and 1001 other things, - you will not find a more comprehensive solution to your queries, whatever time of the day. www.euroheat.co.uk Court Farm Business Park, Bishops Frome, Worcestershire WR6 5AY Pre sales:...

Table of Contents