Euroheat FB50 Installation And Servicing

Euroheat FB50 Installation And Servicing

Gas insert conventional flue
Hide thumbs Also See for FB50:

Advertisement

Installation and Servicing
Insert FB50 & FB80 Gas
Insert Conventional Flue
Part No.
Euroheat Distributors
(H.B.S.) Ltd.,
Unit 2, Court Farm
Serial Number
Business Park,
Bishops Frome,
Worcestershire,
WR6 5AY.
1
E & OE
Instructions Part number IN1084 Ed D
© EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FB50 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Euroheat FB50

  • Page 1 Insert FB50 & FB80 Gas Insert Conventional Flue Part No. Euroheat Distributors (H.B.S.) Ltd., Unit 2, Court Farm Serial Number Business Park, Bishops Frome, Worcestershire, WR6 5AY. E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...
  • Page 2: Table Of Contents

    Contents FB50 Gas Insert Conventional Flue Technical Data FB80 Gas Insert Conventional Flue Technical Data Safety Precautions Installation Of The Gas Supply Housing requirements. Insert aperture requirements Flue and Chimney Requirements General Flue Advice Insert Construction Methods Insert Aperture Construction Housing construction, when using an existing chimney breast.
  • Page 3: Fb50 Gas Insert Conventional Flue Technical Data

    FB50 Gas Insert Conventional Flue Technical Data Model Number 499942 Heat Output Natural Gas 5.1kW (17,400BTU) LP Gas 4.7kW (16,000BTU) Gas Input Natural Gas 6.3kW (21,500BTU) LP Gas 5.6kW (19,100BTU) Heat Control Mertik Gas Valve:- Manual Control or Remote control option.
  • Page 4: Fb80 Gas Insert Conventional Flue Technical Data

    Ø Mbar Pressure G20H 0.95 0.38 4 x 1.17 2.9mbar 99-03 19mbar Nat Gas ³/h ³/h 4 x 0.75 0.68kg/h 36.4mbar 0.33kg/h 8.9mbar 98-24 E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...
  • Page 5: Safety Precautions

    1: On the front page of this manual. 2: On the front page of the operating instructions. 3: On the inside of the lower door. 4: On the warranty registration form. E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...
  • Page 6: Installation Of The Gas Supply

    Do not place furniture or furnishing within 1 metre of the insert. Do not obstruct the area directly beneath the insert as this may block the passage of air into the appliance. E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...
  • Page 7: Housing Requirements

    Minimum insert aperture requirements FB50 Insert. FB80 Insert A= Slot in installation A= Slot in installation B= Build in installation B= Heat vent installation E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...
  • Page 8: Insert Aperture Requirements

    flue system, please follow the applicable installation method. Important in all installations the flue outlet of the appliance must be connected to the chimney system with connecting flue pipe. E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...
  • Page 9: Flue And Chimney Requirements

    fire resistant sealant. It is also recommended that a physical retention method be used at the flue spigot joint, self tapping screws being favoured. E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...
  • Page 10: General Flue Advice

    This does not need to be ridged on a gas installation where the flexible liner may fit directly into the flue spigot. Closure plate Insulation E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...
  • Page 11: Insert Construction Methods

    Full insert venting to room of installation. Venting by open chamber and insert convection E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...
  • Page 12 The hit and miss covers should be designed so that objects cannot pass into the ducting. E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...
  • Page 13: Insert Aperture Construction

    This is not something to be attempted by anyone without specialist knowledge and experience. E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...
  • Page 14 “glasroc” may well be found to be a more cost and time effective solution. E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...
  • Page 15 Rockwool or several layers of Glasrock are suitable. Lintel Insulation material Single thickness of brick Insulation material E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...
  • Page 16: Construction By Modern Building Practices

    E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...
  • Page 17: Construction Of Surround In Properties With A Timber Style Construction

    The provision of insulation and air flow will also apply to the heat reaching the ceiling of the room and this will need extra care if the chimney is to be routed internally through the property. E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...
  • Page 18: Special Insulation Requirements

    Glasroc,and a full range of jointing and fixing accessories and tools. Information can be obtained from local builders merchants or from the British Gypsums web site. www.british-gypsum.bpb.co.uk E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...
  • Page 19: Installation Of Vent Duct Tubes

    fitted. E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...
  • Page 20: The Hearth And Fire Surround

    All stone must have provision for uneven expansion. A fire guard must be fitted if children or infirm adults are at risk of coming into contact with the stove. E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...
  • Page 21: Free Air And Vent Positioning

    E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...
  • Page 22 E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...
  • Page 23: Fitting The Coal Effect

    fl ames. Small Coals 8 = Horse Shoe Coal 4, 5 & 9 Small Coals 1,2,3,6,7 = Large coals E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...
  • Page 24: Gas Control Valve

    For full operating instructions see operation manual. Removing Gas Valve Cover Plate and Adjustment Screws P i l o t adjustment Remove screw and gently remove cover Low operation bypass E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...
  • Page 25: Mertik Maxitrol Gv34 Gas Valve

    The manual control will On/Off set the output from the Pilot Setting and burner, varying from Ignition Control maximum to minimum output or any setting in between. E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...
  • Page 26 (The flat blade screw can be accessed through a hole in the bottom plate of the stove under the valve, anti clockwise to increase, clockwise to decrease.) E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...
  • Page 27 2 x larger connectors fit to the motor. Note these two connectors are different in size and fit only to the appropriate sized connector on the motor. Receiver location Place the receiver out side the appliance away from heat.. E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...
  • Page 28: Removing Gas Burner

    Loosen and disconnect gas supply pipe. Remove burner retaining bolts. When fitting main gas burner nozzle ensure sealing washes are fitted. Main burner Jet Sealing Washer E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...
  • Page 29: Changing Gas Operating Type

    The Air Collar should be adjusted to its a 5 mm wide opening. maximum setting, giving the widest opening to the mixing tube. Maximum 5 mm E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...
  • Page 30: Pilot Assembly

    Position a smoke match just above the furnace door and check that all the smoke is drawn into the opening to the flue diverter. E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...
  • Page 31 If there are any extractor fans in the room or adjacent rooms, these must be running at maximum setting with all interconnecting doors left open, and the spillage test repeated. E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...
  • Page 32 Carry out a gas supply pressure test with the appliance operating. Attach a manometer to the supply pressure test nipple. If the pressure is below requirements inspect gas pipe installation for possible problems. E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...
  • Page 33: Users Manual

    For the latest editions of all Euroheat documentation visit our web site www.euroheat.co.uk. We would request that you inform Euroheat of information which you feel is not provided in this document which would assist other users in the future.
  • Page 34: Service Record

    Locality Name ......................... Post Town ..............When this form been County ..............completed contact Euroheat for Post Code ..............additional Service records Telephone Number ............E & OE Instructions Part number IN1084 Ed D © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Dec 2004...

This manual is also suitable for:

Fb80

Table of Contents

Save PDF