Component Access/Duct Cover Removal
Model ZV850, Island Hood
WARNING: Stop screw must be installed in one
of the support frame holes. Failure to do so may
cause personal injury or damage to duct cover.
1. Lift the lower duct cover up into the upper duct
cover (see illustration).
2. Remove the stop screw from the service
manual envelope.
3. Install stop screw in 1 of the holes provided in
the support frame to secure the lower duct
cover.
Note: Return the stop screw to the service manual
envelope when service is complete.

Control PCB Replacement

Motor Capacitor
Black Box
Control PCB
1. Access black box (refer to Component Access/Duct Cover Removal).
2. Disconnect motor capacitor connection from terminal CN3.
3. Disconnect entry/display assembly cable from terminal CN5.
4. Disconnect filter microswitch and triac connector from terminal CN4A.
5. Disconnect transformer and fuse connector from terminal CN4B.
6. Replace control PCB with new control PCB.
Note: When reinstalling, ensure that all electrical connections are securely fastened.