11.4.5. PIPE INSULATION

1. Please carry out insulation at pipe connection portion as mentioned in Indoor/Outdoor Unit Installation Diagram. Please wrap
the insulated piping end to prevent water from going inside the piping.
2. If drain hose or connecting piping is in the room (where dew may form), please increase the insulation by using POLY-E
FOAM with thickness 6 mm or above.
11.4.6. NEW AUTO MODE SELECTION
• This control depends only on the Indoor intake temperature during its mode selection judgement. Outdoor intake temperature
does not affect the judgement.
The New Auto Mode Control can be selected by cutting the jumper JX1 in the Indoor Printed Circuit Board (PCB).