ITEM
Fin Material
Fin Type
Heat Exchanger
Row x Stage x FPI
Size (W x H x L)
Material
Air Filter
Type
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6°C W.B. (42.8°F W.B.)
Item
Power Source (Phase, Voltage, Cycle)
Input Power
Starting Current
Running Current
Power Factor
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
*Maximum over current protection
Number of core
Power Cord
Length
Thermostat
Protection Device
Note
• Specifications are subject to change without notice for further improvement.
UNIT
INDOOR UNIT
Aluminium (Pre Coat)
Slit Fin
2 x 15 x 21
mm
610 x 315 x 25.4
P.P. Honey Comb
One-Touch
Unit
ø
V
Hz
W
A
A
%
A
m
5
OUTDOOR UNIT
Aluminium
Corrugated Fin
2 x 24 x 17
36.4 x 504 x 713
684
Single
230
50
Cooling; 460 (120 ~ 560)
Heating; 620 (115 ~ 920)
3.0
Cooling; 2.2
Heating; 3.0
Cooling; 91
Heating; 90
4.3
2
3 (1.5 mm
)
1.8
Electronic Control
Electronic Control