PROBLEM
Little or no solution flow to the floor
No power to machine
Little or no propel
Solution tank empty
Solution flow turned off or set too
low
Solution strainer plugged
Solution hoses obstructed
Solution solenoid valve
obstructed or stuck
Vent hole in solution tank lid
obstructed
Battery disconnected
Emergency shut-off activated (If
included)
Battery connections corroded
Faulty main contactor
Faulty key switch
Low battery charge
Wheels spin
Controller overheated
Loose connection
86400390 Manual Operators - Cutter Euro 24V Deluxe
CAUSE
Fill solution tank
Turn on or increase flow setting
Clean solution strainer
Clear obstruction from hose
Clean or replace
Clear obstruction from vent hole
Check all battery cable connec-
tions
Reset
Clean connections
Replace contactor
Replace switch
Charge batteries
Decrease brush pressure
Allow cool down period
Adjust brush shroud if needed
Check motor wires and connec-
tion