NOTE: Entry of a number other than one specified will give unpredictable results.
For fields *43-*46: Enter 0–9; #+11 for B; #+12 for C; #+13 for D; #+14 for E; #+15 for F. Enter [ ] as the fourth digit if a 3-digit account number (for 3+1 dialer
reporting format) is used. Enter 0 as the first digit of a 4-digit account number for Nos. 0000-0999. Exit field by pressing
digits are used. E.g., For Acct. B234, enter: #+11| 2 | 3 | 4
43 PARTITION 1 PRIMARY SUBS. ACCT. No.
44 PARTITION 1 SECONDARY SUBS. ACCT. No.
45 PARTITION 2 PRIMARY SUBS. ACCT. No.
46 PARTITION 2 SECONDARY SUBS. ACCT. No.
47
PHONE SYSTEM SELECT
48
REPORT FORMAT
49
SPLIT/DUAL REPORTING
15 SEC DIALER DELAY (BURG)
50
53
SESCOA/RADIONICS SELECT
54
DYNAMIC SIGNALING DELAY
DYNAMIC SIGNALING PRIORITY
55
TO PROGRAM SYSTEM STATUS, & RESTORE REPORT CODES ( 59 – 76, & 89):
For 3+1 or 4+1 Standard Format: Enter a code in the first box: 1–9, #+10 for 0, #+11 for B, #+12 for C, #+13 for D, #+14 for E, #+15 for F.
A 0 ( not #+10) in the first box will disable a report. A 0 ( not #+10) in the second box will result in automatic advance to the next field.
For Expanded or 4+2 Format: Enter codes in both boxes (1st and 2nd digits) for 1–9, 0, or B–F, as described above.
A 0 ( not #+10) in the second box will eliminate the expanded message for that report. A 0 ( not #+10) in both boxes will disable the report.
For Ademco Contact ID® Reporting: Enter any digit (other than 0) in the first box, to enable zone to report (entries in the second boxes are ignored).
A 0 ( not #+10) in the first box disables the report.
SYSTEM STATUS REPORT CODES ( 59– 68)
59
EXIT ERROR REPORT CODE
60
TROUBLE REPORT CODE
61
BYPASS REPORT CODE
62
AC LOSS REPORT CODE
63
LOW BAT REPORT CODE
64
TEST REPORT CODE
65
OPEN REPORT CODE
66
ARM AWAY/STAY RPT CODE
| | |
| | |
|
|
|
|
[1]
primary
[0]
[0]
[0]
UL: see installation instructions for requirements
[0]
See box above.
|
[00]
See box above.
|
[00]
See box above.
|
[00]
See box above.
|
[00]
See box above.
|
[00]
See box above. Use Scheduling mode to set periodic test reports.
[0,0,0]
Part. 1 Part. 2 Common
Away Stay
Away Stay
Part. 1
Part. 2
– 4 –
See box above for entries. To clear entries
[FFFF]
from field, press * 43 *.
See box above for entries. To clear entries
[FFFF]
from field, press * 44 * .
See box above for entries. To clear entries
|
[FFFF]
from field, press * 45 * .
See box above for entries. To clear entries
|
[FFFF]
from field, press * 46 * .
If Cent. Sta. IS NOT on a WATS line:
0=Pulse Dial; 1=Tone Dial;
if Cent. Sta. IS on a WATS line:
2 = Pulse Dial ; 3 = Tone Dial
0 = 3+1, 4+1 ADEMCO L/S STANDARD
[70]
1 = 3+1, 4+1 RADIONICS STANDARD
secondary
2 = 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD
6 = 4+2 ADEMCO EXPRESS
7 = ADEMCO CONTACT ID® REPORTING
8 = 3+1, 4+1 ADEMCO L/S EXPANDED
9 = 3+1, 4+1 RADIONICS EXPANDED
0 = Disable (Backup report only)
Primary Phone No.
Phone No.
1 = Alarms, Restore, Cancel
2 = All except Open/Close, Test Open/Close,
3 = Alarms, Restore, Cancel
4 = All except Open/Close, Test All
5 = All
0 = no UL: must be "0"; 1 = yes
0 = Radionics (0-9, B-F)
1 = SESCOA (0-9 only reporting)
Select "0" for all other formats.
Delay selectable from 0 to 225 secs in 15-sec
[0]
increments.
0 = no delay (both signals sent), 1 = 15 secs,
2 = 30 secs, etc. UL: must be "0"
0 = Primary Dialer first; 1 = Long Range Radio
[0]
first.
See box above.
[0,0,0,0,0,0] See box above.
Away Stay
Common
(and press next field number) if only 3
Second
Others
Test
All
All