FEATURES AND CONTROLS
Function
Water in Fuel
Cooling System
Problem
Oil Level is Critically
Low
Oil Pump Failure
Warning Horn
Sound
Four Beeps every 2
Minutes
Continuous
Continuous
Continuous
39
Description
Water in the water
separating fuel filter reaches
the full level. Water can be
removed from the filter.
Refer to Maintenance -
Fuel System for filter
removal.
Engine Guardian System is
activated. Power limit will
vary with level of overheat.
Shift outboard into neutral
and check for a steady
stream of water coming out
of the water pump indicator
hole. If no water is coming
out of the water pump
indicator hole or flow is
intermittent, stop engine
and check water intake
holes for obstruction. The
Guardian System must be
RESET before engine will
operate at higher speeds.
Moving throttle lever back to
idle resets the system.
Engine Guardian System is
activated. Power will be
limited. The oil level is
critically low in the engine
mounted oil reservoir. Refill
the engine mounted oil
reservoir along with the
remote oil tank.
Engine Guardian System is
activated. Power will be
limited. The warning horn is
activated if the oil pump
should ever stop functioning
electrically. No lubricating
oil is being supplied to the
engine.