Connecting The Safety Switch; Checking The Function Of The Start Inhibitor - Pfaff 3734 -12 Instruction Manual

Table of Contents

Advertisement

8

Connecting the safety switch

.02.05
2
1
Fig. 8 - 09
8

Checking the function of the start inhibitor

.02.06
Switch the machine on at the main switch and tilt back the sewing head.
The error message „STOP" must appear on the control panel.
If the message does not appear, check the setting of switch 3.
After the sewing head has been set upright, the machine is ready for operation again.
Mounting and commissioning the machine
STOP
2.5
2.5
Connect plug 1 of safety switch 2 as
shown in Fig. 8-09.
When the sewing head is tilted
back, the safety switch
prevents the machine starting
when the main switch is on.
8 - 6

Advertisement

Table of Contents
loading

This manual is also suitable for:

3734 -21

Table of Contents