Alarm Memory Display; Zone Bypassing - DSC PC1550 Instruction Manual

Hide thumbs Also See for PC1550:
Table of Contents

Advertisement

ENTRY DELAY OFF ARMING
If you wish to arm your system and eliminate
the entry delay, enter [*][9] before your access code. The "Armed" light will flash
as a reminder that the system is armed and has no entry delay. An entry through
any zone programmed as a delay zone will create an instant alarm.
e.g. To arm without entry delay.....Press [[*][9][Access Code]
DISARMING
Enter the premises only through the door indicated by your
installer as the entry/exit door. The keypad sounder will be ON. Go to the keypad
and enter the [4 digit access code]. If an error is made entering the code, press
the [#] key and enter the code again. The "Armed" light will go out and the
keypad sounder will stop. A correct access code must be entered before the
allowed entry time expires. The entry delay time may be changed by the installer.
If an alarm occurred while the panel was armed, the "Memory" light and the light
for the zone which caused the alarm will start to flash and will continue flashing
for 2 minutes. At the end of 2 minutes, the keypad lights will stop flashing and the
keypad will return to the normal Ready condition.
If you return home and find an alarm has occurred while you were away, it is
possible that an intruder may still be on the premises. Go to a neighbor's and if
your system is monitored, call the monitoring station. They will advise what action
has been taken as a result of the alarm and whether the premises are safe to
enter. If your system is not monitored, call the local police to investigate.

ALARM MEMORY DISPLAY

If the "Memory" light is on, an alarm has
occurred since the last time the panel was armed. The alarm memory will
automatically be displayed when the system is disarmed (see Disarming).
Press the [*] then [3] keys to display which zone caused the alarm.
The alarm memory will be cleared when the panel is re-armed. Press the [#] key
to return to Ready.

ZONE BYPASSING

Bypassed zones do not cause an alarm. Use zone
bypassing when access is needed to part of the protected area. Also, damaged
wiring or contacts on a zone may be temporarily bypassed until repairs can be
made so that the panel can be armed.
To bypass zones, enter [*][1][Access Code] and the zone numbers to be
bypassed. i.e. [1] for zone 1, [6] for zone 6. If the [0] key is pressed instead of a
zone number, all zone bypasses will be removed. If the [9] key is pressed, the
last group of zones which was bypassed will be recalled. Press [#] to return to
Ready.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents