Alarm Test

*
Enter [
][6][Master Code][8] for a 2-second test of the keypad lights,
keypad buzzer, battery and the bell/siren.
Press [#] to return to Ready.

Programming Security Codes

The Master Code
*
Enter [
][5][current Master Code][1][new Master Code]
Press [#] to return to Ready.
Record your new Master Code on the System Information page in this
booklet.
Additional Codes
Up to 5 additional access codes (2 through 6) may be programmed. The
6th access code may be established by your installer as a One-Time use
code.
T T T T T o pr
o pr
o program a new code:
o pr
ogram a new code:
ogram a new code:
ogram a new code:
o pr
ogram a new code:
*
Enter [
][5][Master Code][code number][new 4 digit code]
The [code number] is a single digit either 2, 3, 4, 5 or 6.
Press [#] to return to Ready.
If an access code already exists, it will be replaced by the new code.
Record your new code(s) on the System Information page in this book.
T T T T T o r
o r
o r
o remove a code:
o r
emove a code:
emove a code:
emove a code:
emove a code:
Enter [
*
][5][Master Code][code number][
The [code number] is a single digit either 2, 3, 4, 5 or 6.
Press [#] to return to ready.
Do not erase the Master Code (code number 1).
NOTE: It is recommended that the factory default Master Code [1234] not be used.
One-Time Use Code
The One-Time Use code is designed for entry and exit of the premises for
one occasion only. The panel must be programmed by the installer for this
option to be enabled. The 6th access code is the one-time code.
To use this code, enter your one-time code as the 6th access code using
the previously described commands. When you leave the premises, arm
your system with any access code except the newly entered one-time use
code. This one-time code is given to a person (e.g. a maid) who will enter
the premises while the system is armed and you are away.
The one-time code user enters the premises and disarms the system using
the one-time access code. Upon leaving, the same code is used to arm the
system. As soon as the system is armed, the one-time code is erased and
can not be used to re-enter the premises. A different code can be provided
each time for the one-time user.

Alarm Memory Display

If the "Memory" light is ON, an alarm has occurred during the last armed
period. The alarm memory will automatically be displayed when the system
is disarmed (See Disarming the System).
*
Press [
] then [3] to display the zone which caused the alarm.
Press [#] to return to Ready.
****
]