Montigo B34DV Installation, Operation & Maintenance Manual

B-series dv-2 gas fireplace

Advertisement

B-Series DV-2 Gas Fireplace
Warning:
Improper installation, adjustment, alteration, service or maintenance can cause injury
or property damage. Refer to this manual. For assistance or additional information
consult a qualified installer, service agency
For Your Safety:
Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
C
XG0160
Canadian Heating Products Inc. Langley, BC V4W 4A
Installation Operation & Maintenance Manual
Check local codes and read all instructions prior to installation.
B34DV2 Black Trim
Shown
or the gas supplier.
®
US
www.montigo.com
B34DV
B38DV
Warning:
information in these instructions is
not followed exactly, a fire or explo-
sion may result causing property
damage, personal injury or death.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical
switch; do not use any phone in
your building.
Immediately call your gas
supplier from a neighbor's
phone. Follow the gas supplier's
instructions.
If you cannot reach your gas
supplier, call the fire department.
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
Installer: Leave this manual
with the appliance.
Consumer: Retain this
manual for future reference.
Montigo Del Ray Corp. Ferndale, WA 98248
Indoor
Indoor
If the
151125

Advertisement

Table of Contents
loading

Summary of Contents for Montigo B34DV

  • Page 1 ® • Installer: Leave this manual with the appliance. • Consumer: Retain this manual for future reference. XG0160 Canadian Heating Products Inc. Langley, BC V4W 4A Montigo Del Ray Corp. Ferndale, WA 98248 151125...
  • Page 2: Table Of Contents

    As the owner of this new fireplace, you'll want to read and care- fully follow all the instructions contained in this Installation, Your new Montigo gas fireplace will give you years of durable, Operations and Maintenance manual. Pay special attention to all reliable use.
  • Page 3: Introduction

    Standard Log Set This manual covers all models and unless otherwise specified, the The B34DV-2 is rated for Natural Gas at 18,000 BTU/H (5.28 Kilowatts) Input or Propane at 18,000 BTU/H (5.28 designation B-Series DV-2 refers to all models. Sections which are Kilowatts) Input.
  • Page 4: Rating Plate Sample - B34

    B-Series DV-2 Gas Fireplace Introduction Rating Plate Sample - B34 Figure B: Rating Plate for B34 - Electronic Ignition Figure A: Rating Plate for B34 - Standing Pilot Page 4 Part No. XG0160 -151125...
  • Page 5: Rating Plate Sample - B38

    B-Series DV-2 Gas Fireplace Introduction Rating Plate Sample - B38 Figure D: Rating Plate for B38 - Electronic Ignition Figure C: Rating Plate for B38 - Standing Pilot Page 5 Part No. XG0160 - 151125...
  • Page 6: Installing And Framing The Fireplace

    B-Series DV-2 Gas Fireplace Installation When installing a shelf over the top of the fireplace, the following guidelines Installing and Framing the Fireplace must be adhered to: For Rear Vent applications the minimum clearance The B-Series-DV-2 fireplaces may be installed in any location that from the top of the fireplace to a shelf is 8".
  • Page 7: Installing The Gas Line

    The gas line must be installed before finishing the B-Series DV-2 Use only certified Montigo vent components. (Use of other parts will void the Montigo warranty, and may impede the operation of the Fireplace. Natural Gas requires a minimum inlet gas supply fireplace.)
  • Page 8: Installing Terminations With Built-In Frames

    B-Series DV-2 Gas Fireplace Installation Installing Terminations with Built-In Frames Installing Heat Guards over Terminations MTO-4F (4"/7") PTO-3F (5"/8") MTKOG (4"/7") PTKOG (5"/8") Ensure that the two long mounting brackets are facing the Frame the termination opening to 11" x 11". bottom of the termination.
  • Page 9: Top Vent Venting Runs

    Graph (Fig. 8) or (Fig.8a) with an 'X'. If the 'X' falls on or above the top boundary of the shaded area, the installation is acceptable. B34DV-2 B34DV-2 Example A: (Acceptable Installation) If the vertical dimension from the hearth is 108" and the horizontal run to the wall flange of the vent termination is 180", this would be...
  • Page 10: Horizontal Venting

    B-Series DV-2 Gas Fireplace Installation Example 1: For our shortest venting configuration use components A and E (see table on page 9). Figure 11. Extended Installation using a combination of Figure 9. Typical Top Vent installation. If the 90° elbow is solid and flex venting.
  • Page 11 B-Series DV-2 Gas Fireplace Installation B. Vertical (Through-The-Roof) Installations A maximum of two offsets (each offset has two 90° bends)  Vertical Terminations must be installed:  may be made and shall not exceed total length of 25% of the •...
  • Page 12: Rear Vent Venting Runs

    B-Series DV-2 Gas Fireplace Installation Rear Vent Venting Runs 3. Corner Installation — 45° or less. Use an MTO-4 or MTO-4F termination, an MFL-1 or MFL-2(12" or The B-Series DV-2 Rear Vent has three possible installations 24" compressed length) and a frame, if appropriate. Flex may which do not require vertical lift.
  • Page 13 B-Series DV-2 Gas Fireplace Installation B. Multi-Elbow Installations Installation of Rear Vent DV-2 For more difficult installation situations, the B-Series DV-2 Rear Vent The following venting components are available from a B-Series may be installed with two - 90° elbows and up to 15' of horizontal run. If DV-2 in a Rear Vent Installation: using this installation option, you must adhere to the following guidelines: Important: Some models are not available to be installed in a...
  • Page 14: Finishing Around The Fireplace

    T.V. and radio components. B34DV-2 Figure 22. Combustible mantles and facings for B34DV-2. B34DV-2 WARNING When installing the replace - gas lines, ttings, accesso- ries or any other objects cannot impede the proper movement of the door buckles.
  • Page 15: Wiring

    B-Series DV-2 Gas Fireplace Installation Wiring OPTIONAL BATTERY PACK 1.5V AA type 1.5V AA type SPARK GREEN 1.5V AA type WHITE 1.5V AA type BLACK BLACK SENSOR To PPO TO ON/OFF WHITE BLACK WALL SWITCH BLUE WHITE OPTIONAL CPI/IPI SWITCH YELLOW/GREEN ORANGE GREEN...
  • Page 16 B-Series DV-2 Gas Fireplace Installation CPI [Continuous Pilot Ignition] / IPI [Intermit- Installing the CPI Jumper Cable tent Pilot Ignition] Jumper Cable Installation 1). Access the controller (refer to the installation and on Proflame II Basic Board (only available for maintenance manual for your model).
  • Page 17: Gas Control And Pilot Wiring

    B-Series DV-2 Gas Fireplace Installation Gas Control and Pilot Wiring B-Series DV-2-I Honeywell (Q3450) Pilot Assembly Pilot Electrical Harness Connector Honeywell Gas Control (SV9501M) Gas Control Connector Junction Box Fan Plug Receptacle Black 115VAC White 24VAC Green Gnd Screw 40 VA Transformer Wall Switch Figure 27.
  • Page 18: Removing The Screen And Door

    DIMENSIONS ARE IN INCHES MANUAL 1 REVISIONS TOLERANCES: 02/27/2015 Drawn by FRACTIONAL 1/32" TWO PLACE DECIMAL .015" DWG. NO. B34DV-MAN1 Revision / Date REV. DESCRIPTION DATE CHANGED BY THREE PLACE DECIMAL .005" ALL BENDS ARE ASSUMED Revision MATERIAL TO BE 90 UNLESS NOTED Finish OTHERWISE.
  • Page 19 The trim piece with the Montigo emblem should be installed on the lower middle clips with the emblem on the right side. Figure 29. Installing the Trim.
  • Page 20: Installing The Log Set

    B-Series DV-2 Gas Fireplace Installation Installing the Log Set Single Cast Log Set Installing the Logs: Unpack the log set and handle very carefully. Remove the door cover and the glass door. Place the single cast log. Set firmly in place as shown below. Place the Front log onto the front log rest as shown in figure 30.
  • Page 21: 5-Piece Log Set

    B-Series DV-2 Gas Fireplace Installation 5-Piece Log Set Installing the Logs: Unpack the logs and handle them very carefully. Remove the door cover and the glass door. Place the Back log onto the back log rest as shown below in figure 30c.
  • Page 22 B-Series DV-2 Gas Fireplace Installation Cautions: If logs are not placed properly, excessive sooting will result. The surface of the logs will crack due to the heat of the flames. This is a normal occurrence. Figure 30h. Right log placement. Figure 30i.
  • Page 23: Operation

    B-Series DV-2 Gas Fireplace Operation - Model B-Series DV-2-I B-Series D*-2-I Operation For Your Safety - READ BEFORE LIGHTING: with American Flame Electronic Ignition WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
  • Page 24: Sit Proflame 2 Electronic Ignition

    B-Series DV-2 Gas Fireplace Operation - Model B-Series DV-2-F B-Series D*-2-F SIT Proflame 2 Electronic Ignition Lighting Instructions: 1. STOP! Read the safety information above on this label. 6. Turn fireplace "ON" using wall switch or remote control. 2. Remove the lower Horizontal access panel. 7.
  • Page 25: Honeywell Electronic Ignition

    B-Series DV-2 Gas Fireplace Operation - Model B-Series DV-2-I B-Series D*-2-I Honeywell Electronic Ignition Lighting Instructions: 1. STOP! Read the safety information above on this 7. Flip up the lower trim. label. 8. If the fireplace does not operate, follow the instructions 2.
  • Page 26: Maintenance

    B-Series DV-2 Gas Fireplace Operation - Model B-Series DV-2-F B-Series D*-2-F Maintenance Lighting Instructions See pages 23 to 25. General Have the fireplace and installation inspected yearly. The B-Series DV-2 Burner Adjustment SIT NOVA 820 inspection must include, but is not limited to, the following: The B-Series DV-2 is equipped with an adjustable burner, allowing A visual check of the entire vent system and termination.
  • Page 27: Sit Proflame 2

    If your fireplace still does not operate correctly, consult your local Montigo dealer. All service and repairs should be performed by a qualified Technician. All spare parts, optional fans, and optional trim finishes are available from your local Montigo dealer. Page 27 Part No. XG0160 - 151125...
  • Page 28: Honeywell

    B-Series DV-2 Gas Fireplace Maintenance Troubleshooting B-Series DV-2-I Replacement Parts - B-Series DV-2 Honeywell: B34DV-2 B38DV-2 NG Gas Valve RGC1006 RGC1006 The following is a troubleshooting chart of possible problems: RGC1005 RGC1005 LP Gas Valve NG Pilot RPA020 RPA020 LP Pilot...
  • Page 29: Warranty

    The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
  • Page 30: Appendix A - Termination Locations

    B-Series DV-2 Gas Fireplace Appendix A - Termination Locations Location Canada* USA** 12 inches 12 inches clearance to the termination frame above grade, veranda, porch, deck, or balcony 12 inches 12 inches clearance to top of doors or operable windows 9 inches 12 inches clearance to sides or bottom of door or operable windows...
  • Page 31: Appendix B - State Of Massachusetts

    B-Series DV-2 Gas Fireplace Appendix B - State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft (2) Revise 10.8.3 by adding the following additional requirements:...
  • Page 32 XG0160 - 150204 Canadian Heating Products Inc. Montigo Del Ray Corp. Langley, BC V4W 4A1 Ferndale, WA 98248...

This manual is also suitable for:

B38dv

Table of Contents