Montigo B34DV Indoor Installation, Operation & Maintenance Manual

Montigo B34DV Indoor Installation, Operation & Maintenance Manual

B-series dv-2 gas fireplace

Advertisement

B-Series DV-2 Gas Fireplace
Warning:
Improper installation, adjustment, alteration, service or maintenance can cause
injury or property damage. Refer to this manual. For assistance or additional
information consult a qualified installer, service agency or the gas supplier.

Safety Notice:

Glass doors on gas fireplaces are extremely hot while the fireplace is on and remain
hot even after the fireplace has been turned off. Safety screens are available and
can reduce the risks of severe burns. Please keep children away from the fireplace
at all times.

For Your Safety:

Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
XG0160
Canadian Heating Products Inc. Langley, BC V4W 4A
Installation Operation & Maintenance Manual
Check local codes and read all instructions prior to installation.
B34DV2 Black Trim Shown
®
C
US
www.montigo.com
B34DV
B38DV
Warning:
mation in these instructions is not
followed exactly, a fire or explosion
may result causing property dam-
age, personal injury or death.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical
switch; do not use any phone in
your building.
Immediately call your gas
supplier from a neighbor's
phone. Follow the gas supplier's
instructions.
If you cannot reach your gas
supplier, call the fire department.
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
Montigo Del Ray Corp. Ferndale, WA 98248
Indoor
Indoor
If the infor-
Installer: Leave this manual
with the appliance.
Consumer: Retain this
manual for future reference.
141231

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the B34DV Indoor and is the answer not in the manual?

Questions and answers

Summary of Contents for Montigo B34DV Indoor

  • Page 1: Safety Notice

    • Installer: Leave this manual with the appliance. • Consumer: Retain this ® manual for future reference. XG0160 Canadian Heating Products Inc. Langley, BC V4W 4A Montigo Del Ray Corp. Ferndale, WA 98248 141231...
  • Page 2: Table Of Contents

    Installation, Your new Montigo gas fireplace will give you years of durable, Operations and Maintenance manual. Pay special attention to all reliable use. Welcome to the Montigo family of gas fireplace cautions, warnings, and Important warnings.
  • Page 3: Introduction

    Modification of the fireplace and/or components including Direct-Vent assembly or glass doors. Standard Log Set Use of any component part not manufactured or approved by Montigo in The B38DV-2 is rated for Natural Gas at 21,000 BTU/H (6.16 combination with this Montigo fireplace system.
  • Page 4: Installation

    B-Series DV-2 Gas Fireplace Installation When installing a shelf over the top of the fireplace, the following guidelines Installing and Framing the Fireplace must be adhered to: For Rear Vent applications the minimum clearance fireplaces may be installed in any location that main- B-Series-DV-2 from the top of the fireplace to a shelf is 8".
  • Page 5: Installing The Gasline

    2". the gas supply controls to the appliance. The fireplace gas connection Use only certified Montigo vent components. (Use of other parts will void and the main operating gas valve is located behind the removable trim the Montigo warranty, and may impede the operation of the fireplace.)
  • Page 6: The Remote Switch

    B-Series DV-2 Gas Fireplace Installation Installing Terminations with Built-In Frames Installing Heat Guards over Terminations MTO-4F (4"/7") PTO-3F (5"/8") MTKOG (4"/7") PTKOG (5"/8") Ensure that the two long mounting brackets are facing the bottom Frame the termination opening to 11" x 11". of the termination.
  • Page 7: Top Vent Venting Runs

    B-Series DV-2 Gas Fireplace Installation Top Vent Venting Runs B38DV-2 B38DV-2 For the B-Series DV-2 Top Vent, there are two types of installations: Example A: (Acceptable Installation) A) Through-The-Wall Installations and B) Vertical (Through-The-Roof) If the vertical dimension from the hearth is 84" and the horizontal run to Installations.
  • Page 8 B-Series DV-2 Gas Fireplace Installation Example 1: For our shortest venting configuration use components A and E (see table on page 7). Figure 11. Extended Installation using a combination of solid and flex Figure 9. Typical Top Vent installation. If the 90° elbow is installed venting.
  • Page 9 B-Series DV-2 Gas Fireplace Installation B. Vertical (Through-The-Roof) Installations A maximum of two offsets (each offset has two 90° bends) may be  Vertical Terminations must be installed:  made and shall not exceed total length of 25% of the vertical vent •...
  • Page 10: Rear Vent Venting Runs

    B-Series DV-2 Gas Fireplace Installation Rear Vent Venting Runs 3. Corner Installation — 45° or less. The B-Series DV-2 Rear Vent has three possible installations which Use an MTO-4 or MTO-4F termination, an MFL-1 or MFL-2(12" or 24" do not require vertical lift. compressed length) and a frame, if appropriate.
  • Page 11 B-Series DV-2 Gas Fireplace Installation B. Multi-Elbow Installations Installation of Rear Vent DV-2 For more difficult installation situations, the B-Series DV-2 Rear Vent The following venting components are available from a B-Series DV-2 may be installed with two - 90° elbows and up to 15' of horizontal run. If in a Rear Vent Installation: using this installation option, you must adhere to the following guidelines: 4"...
  • Page 12: Finishing Around The Fireplace

    B-Series DV-2 Gas Fireplace Installation Finishing Around the Fireplace Mantels & Surrounds NOTE: National Canadian Gas Association mantel test requirements Combustible mantels and mouldings may be safely installed over the are for fire hazard prevention to combustible materials. top and on the front of the fireplace provided that they do not project beyond shaded area shown in Figure 22 or 22a.
  • Page 13: Wiring

    B-Series DV-2 Gas Fireplace Installation Wiring OPTIONAL BATTERY PACK 1.5V AA type 1.5V AA type SPARK GREEN 1.5V AA type WHITE BLACK 1.5V AA type BLACK SENSOR To PPO TO ON/OFF WHITE BLACK WALL SWITCH BLUE WHITE OPTIONAL CPI/IPI SWITCH YELLOW/GREEN ORANGE GREEN...
  • Page 14 B-Series DV-2 Gas Fireplace Installation Gas Control and Pilot Wiring B-Series DV-2-I Honeywell (Q3450) Pilot Assembly Pilot Electrical Harness Connector Honeywell Gas Control (SV9501M) Gas Control Connector Junction Box Fan Plug Receptacle Black 115VAC White 24VAC Green Gnd Screw 40 VA Transformer Wall Switch Figure 26.
  • Page 15: Removing And Installing The Door

    B-Series DV-2 Gas Fireplace Operation - Model B-Series DV-2 Removing and Installing the Door n t ing the og : The 6 horizontal trim pieces (3 upper and 3 lower) are purchased separate Removing the door: Remove the trim (Figure 28) to access the door latches.
  • Page 16: Positioning The Log Set

    B-Series DV-2 Gas Fireplace Installation Installing the Log Set Installing the Logs: The B-Series DV2 is supplied with five ceramic fibre logs. Unpack the logs and handle them very carefully. Remove the door cover and the glass door. Place the Back log onto the back log rest as shown below in figure 29.
  • Page 17: Lighting Instructions

    B-Series DV-2 Gas Fireplace Operation - Model B-Series DV-2 B-Series D*-2 Standing (Continuous) Pilot Ignition (SIT NOVA 820) For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 18: Sit Proflame 2 Electronic Ignition

    B-Series DV-2 Gas Fireplace Operation - Model B-Series DV-2-F B-Series D*-2-F SIT Proflame 2 Electronic Ignition with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
  • Page 19: Honeywell Electronic Ignition

    B-Series DV-2 Gas Fireplace Operation - Model B-Series DV-2-I B-Series D*-2-I Honeywell Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. If you cannot reach your gas supplier, call the Fire A.
  • Page 20: Operation

    B-Series DV-2 Gas Fireplace Operation Maintenance Lighting Instructions General Have the fireplace and installation inspected yearly. The inspection See pages 17 to 19. must include, but is not limited to, the following: B-Series DV-2 Burner Adjustment SIT NOVA 820 • A visual check of the entire vent system and termination.
  • Page 21: Troubleshooting

    If your fireplace still does not operate correctly, consult your local Montigo dealer. All service and repairs should be performed by a qualified Technician. All spare parts, optional fans, and optional trim finishes are available from your local Montigo dealer. Part No. XG0160 - 141231 Page 21...
  • Page 22: Spare Parts

    B-Series DV-2 Gas Fireplace Maintenance Troubleshooting B-Series DV-2-I Spare Parts - B-Series DV-2 Honeywell: B34DV-2 B38DV-2 RGC1006 RGC1006 NG Gas Valve The following is a troubleshooting chart of possible problems: LP Gas Valve RGC1005 RGC1005 NG Pilot RPA020 RPA020 RPA021 RPA021 LP Pilot Burner NG Front...
  • Page 23: Warranty

    The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
  • Page 24: Termination Locations

    B-Series DV-2 Gas Fireplace Appendix A - Termination Locations Location Canada* USA** clearance to the termination frame above grade, veranda, porch, deck, or balcony 12 inches 12 inches clearance to top of doors or operable windows 12 inches 12 inches 9 inches 12 inches clearance to sides or bottom of door or operable windows...
  • Page 25: B State Of Massachusetts / Amendment

    B-Series DV-2 Gas Fireplace Appendix B - State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft (2) Revise 10.8.3 by adding the following additional requirements:...
  • Page 26 XG0160 - 141231 Montigo Del Ray Corp. Canadian Heating Products Inc. Ferndale, WA 98248 Langley, BC V4W 4A1...

This manual is also suitable for:

B38dv indoor

Table of Contents